Status Reporting System (Option R&S
FSV-K70)
R&S
®
FSV-K70
336
Operating Manual 1176.7578.02 ─ 09
5.4 STATus:QUESTionable:MODulation<n>:EVM Register
This register comprises information about limit violations in EVM evaluation. It can be
queried with commands
STATus:QUEStionable:MODulation<n>:EVM:CONDition
and
STATus:QUEStionable:MODulation<n>:EVM[:EVENt]
.
Bit No
Meaning
0
Error in current RMS value
1
Error in mean RMS value
2
Error in peak RMS value
3-4
These bits are not used
5
Error in current peak value
6
Error in mean peak value
7
Error in peak peak value
8-15
These bits are not used
5.5 STATus:QUESTionable:MODulation<n>:PHASe Reg-
ister
This register comprises information about limit violations in Phase Error evaluation. It
can be queried with commands
STATus:QUEStionable:MODulation<n>:PHASe:CONDition
and
STATus:QUEStionable:MODulation<n>:PHASe[:EVENt]
.
Bit No
Meaning
0
Error in current RMS value
1
Error in mean RMS value
2
Error in peak RMS value
3-4
These bits are not used
5
Error in current peak value
6
Error in mean peak value
7
Error in peak peak value
8-15
These bits are not used
STATus:QUESTionable:MODulation<n>:PHASe Register
Содержание FSV-K70
Страница 368: ...Formulae and Abbreviations R S FSV K70 368 Operating Manual 1176 7578 02 09 Formulae ...
Страница 370: ...Formulae and Abbreviations R S FSV K70 370 Operating Manual 1176 7578 02 09 Formulae ...
Страница 371: ...Formulae and Abbreviations R S FSV K70 371 Operating Manual 1176 7578 02 09 Formulae ...
Страница 372: ...Formulae and Abbreviations R S FSV K70 372 Operating Manual 1176 7578 02 09 Formulae ...