Remote Control Commands - R&S
FSV-K70
R&S
®
FSV-K70
225
Operating Manual 1176.7578.02 ─ 09
Query parameters:
<type>
<none>
Average EVM value of current sweep
AVG
RMS average EVM value (over several sweeps)
RPE
Peak value of EVM (over several sweeps)
SDEV
Standard deviation of EVM values over several sweeps
PCTL
95% percentile of RMS value (over several sweeps)
PEAK
Maximum EVM over all symbols of current sweep
PAVG
Average of maximum EVM values over several sweeps
TPEA
Maximum EVM over all symbols over several sweeps
PSD
Standard deviation of maximum EVM values over several
sweeps
PPCT
95% percentile of maximum RMS values over several sweeps
*RST:
PEAK
Usage:
Query only
Mode:
VSA
CALCulate<n>:MARKer<m>:FUNCtion:DDEMod:STATistic:FDERror?
<type>
This command queries the results of the FSK deviation error of FSK modulated sig-
nals.
Suffix:
<n>
.
1..4
screen number
<m>
1..4
irrelevant
CALCulate subsystem