Example: measurement of a GSM EDGE pattern that has a length of 26 symbols.
Figure 6-10: User Pattern for Sync = Off
Figure 6-11: User Pattern for Sync = On
●
Choose a longer "Result Range".
●
If the signal is bursted and the bursts are short:
–
Make sure your "Result Range" comprises the entire burst.
–
Make sure that "Run-In/Out" is not chosen too large, since the "Run-In/Out"
ranges are excluded from the synchronization.
●
If the signal is bursted and contains a pattern:
Only switch off the burst search if absolutely necessary. If you need to switch it off,
align your "Result Range" to the pattern, make sure it does not exceed the burst
ramps and choose "Continuous Signal" as the "Signal Type" in the "Signal Descrip-
tion" dialog.
For more information, see
●
Chapter 2.4, "Demodulation Overview"
Message: Sync Prefers Longer Pattern
This message can only occur if the coarse synchronization is data-aided, i.e is based
on a known pattern. In case the pattern is very short, pattern-based coarse synchroni-
zation might be unstable. If demodulation is stable, e.g. you get a reasonable EVM,
there is no need to change anything. Otherwise, you have two options:
●
Switch to the non-pattern-based mode by setting the parameter "Coarse Synchro-
nization: Data "
(see
●
If possible, use a longer pattern.
For more information, see
●
Chapter 2.4, "Demodulation Overview"
Explanation of Error Messages
Содержание FSV-K70
Страница 368: ...Formulae and Abbreviations R S FSV K70 368 Operating Manual 1176 7578 02 09 Formulae ...
Страница 370: ...Formulae and Abbreviations R S FSV K70 370 Operating Manual 1176 7578 02 09 Formulae ...
Страница 371: ...Formulae and Abbreviations R S FSV K70 371 Operating Manual 1176 7578 02 09 Formulae ...
Страница 372: ...Formulae and Abbreviations R S FSV K70 372 Operating Manual 1176 7578 02 09 Formulae ...