Instrument Functions for Vector Signal Analysis
R&S
®
FSV-K70
105
Operating Manual 1176.7578.02 ─ 09
Figure 3-24: Evaluation lines in absolute magnitude diagram
In symbol tables, the evaluated symbols are indicated by red square brackets.
In other result displays that are based on the evaluation range only, two red vertical
lines are displayed in the diagram header to indicate a limited evaluation basis.
3.1.7 Saving Measurement Results
After a data acquisition or measurement, you may like to save the results for further
evaluation or documentation purposes. You can save a screenshot of the display to a
file or print it, and you can export the trace data in ASCII format.
To print or store a screenshot
1. Press the PRINT key.
2. Press the "Device Setup" softkey.
3. To copy the screenshot to the clipboard or print it on a printer, select the corre-
sponding option. Before you print to a printer, make sure a printer is installed (see
the description in the base unit manual).
To save the screenshot to a file, select the file format for your screenshot (e.g.
JPEG
) and then select the "Print to file" option.
4. Close the "Hardcopy Setup" dialog.
5. Press the "Colors" softkey and then "Select Print Color Set".
Measurement Result Display
Содержание FSV-K70
Страница 368: ...Formulae and Abbreviations R S FSV K70 368 Operating Manual 1176 7578 02 09 Formulae ...
Страница 370: ...Formulae and Abbreviations R S FSV K70 370 Operating Manual 1176 7578 02 09 Formulae ...
Страница 371: ...Formulae and Abbreviations R S FSV K70 371 Operating Manual 1176 7578 02 09 Formulae ...
Страница 372: ...Formulae and Abbreviations R S FSV K70 372 Operating Manual 1176 7578 02 09 Formulae ...