background image

 

Page 1 of 20 

INSTRUCTION  MANUAL

 

M

X Series Pulser Options

  

Macnaught MX flowmeter series 

MXL-INST-PULSE 

Rev 3 

04/2016 

T

O

 

THE

 

OWNER

 

This manual contains connection and operating instructions for a selection of Pulse output options. 
Please read and retain this instruction manual to assist you in the operation and maintenance of these products. 
 
In addition Macnaught offer a comprehensive set of online support materials to compliment this instruction  
manual. You can access the website by scanning the QR code or visiting the Macnaught website 
www.macnaughtflowmeasurement.com.au 
 
 
 
 

Содержание MX Series

Страница 1: ...for a selection of Pulse output options Please read and retain this instruction manual to assist you in the operation and maintenance of these products In addition Macnaught offer a comprehensive set...

Страница 2: ...uction Page 5 Overview Page 6 INDEX Locking Facility Page 7 Wiring Instructions Reed Hall Module Page 8 Wiring Instructions Dual Hall Module Page 9 Sensor cable Page 10 Field Connector Page 11 Industr...

Страница 3: ...ns the raw pulse input signal to display volume of fluid passed e g Displays 1 Litre for every 36 pulses received The Active Rotor is fitted with magnets Flow Direction It is recommended the Reed Swit...

Страница 4: ...l Effect IC Solid State Sensor Maximum Sensor Supply Current 7 5mA Maximum Output Current 25mA Operating Voltage 4 5V to 24V DC Transistor Type Open Collector NPN Note Contact rating maximum is 10W Ne...

Страница 5: ...the below is available on the following page Sensor options Reed and Hall effect sensor Dual Hall Effect sensor Please see pages 4 for electrical specifications and pages 8 9 for the wiring instructi...

Страница 6: ...ensor Options Field Connector Part number MXD CF Sensor Cable 1 5 meters Part number MXD C1 5 Sensor Cable 5 meters Part number MXD C5 Sensor Cable 10 meters Part number MXD C10 Part number MXD HH Hal...

Страница 7: ...s is enabled by fitting the special Locking screw supplied with every Pulser Module 1 Fit DIN Pulse Module to the flowmeter 2 Locate the Lock symbol and remove existing screw 3 Replace with the Lockin...

Страница 8: ...Page 8 of 20 Pin designation M12 male connector Contact designation M12 cable Contact designation M12 field connector WIRING INSTRUCTIONS REED HALL MODULE PART NUMBER MXD RH...

Страница 9: ...in designation M12 male connector Contact designation M12 cable Contact designation M12 field connector Schematic diagram Schematic diagram Schematic diagram WIRING INSTRUCTIONS DUAL HALL MODULE PART...

Страница 10: ...ody TPU thermoplastic polyurethane Knurled section zinc die cast nickel plated Rated voltage current 60v 4A Contact resistance Max 5 m Ambient temperature plug and socket 25 C 90 C Technical Specifica...

Страница 11: ...sitions 5 Protection IP67 Connection method screw connection Conductor cross section 0 25mm 0 75mm Material of body PTB Material of knurled section nickel plated brass Sealing material NBR nitrile rub...

Страница 12: ...ploded diagram 1 Remove the 4 socket head cap screws holding the INDUSTRIAL PULSER CAP to the BASE PLATE Take care not to lose the gasket 2 Lift the PULSER CAP to expose the terminal block for the con...

Страница 13: ...Page 13 of 20 INDUSTRIAL PULSE CAP EXPLODED DIAGRAM Pulser Cap Screws Pulser Cap Pulser Cap Gasket PCB screws PCB Circlip Base Plate Flowmeter...

Страница 14: ...luminium Protection IP67 Ambient Temperature operation 25 C 120 Cable Gland Entry NPT or M20x1 5 Part Numbers MXD ACM 1 sensor Reed Hall gland entry M20x1 5 MXD ACM 2 sensor Dual Hall gland entry M20x...

Страница 15: ...Page 15 of 20 INDUSTRIAL PULSE CAP PCB TERMINAL BLOCK TERMINAL BLOCK BASE PLATE...

Страница 16: ...length 6mm Connection Data Conductor cross section solid min 0 14mm 2 Conductor cross section solid max 0 5mm 2 Conductor cross section flexible min 0 2mm 2 Conductor cross section flexible max 0 5mm...

Страница 17: ...Page 17 of 20 Reed Hall Effect configuration Dual Hall Effect configuration INDUSTRIAL PULSE CAP WIRING DIAGRAMS...

Страница 18: ...Page 18 of 20 NOTES...

Страница 19: ...its policy and ask you to be aware of how to dispose of this product The crossed out wheelie bin symbol illustrated and found on our products signifies that this product should not be disposed of in g...

Страница 20: ...Page 20 of 20...

Отзывы: