- 174 -
Give current unit
Command overview: command returns current unit.
Format:
UG CR LF
Response options:
UG_x_OK CR LF
– command carried out, response: current unit
UG_I CR LF
– command understood but not accessible at this moment
x
– parameter, unit symbol
An example:
Command:
UG CR LF
– return current unit
Response:
UG_ct_OK CR LF
– currently set unit is „ct”
Cooperation with PUE 7.1, PUE 10 terminal
Format:
NT CR LF
Response options:
ES CR LF
- command not understood (format error)
MASS FRAME
- response: mass value in a basic measuring unit
Response format:
1
2
3
4
5
6
7
8
9
-18
19
20
-
22
23
24
-
32
33
34
-
36
37
38
39
40
N
T
s
pac
e
s
tabi
lit
y
m
ar
k
er
z
er
o
m
ar
k
er
range
m
ar
k
er
di
gi
t
m
ar
k
er
s
pac
e
m
a
s
s
s
pac
e
m
as
s
uni
t
s
pac
e
ta
re
s
pac
e
tar
e uni
t
s
pac
e
H
idden
di
gi
ts
quant
it
y
CR
LF
NT
- command
Stability marker
- [space] if stable, [?] if unstable
Zero marker
- [space] for any value but zero, [Z] for zero value
Range marker
- marker informing on range within which mass value is comprised:
[space] I range balance, [2] II balance, [3] III balance
Digit marker
-[zero] no digit, [1] one digit marker, [2] two digits marker, [3] three
digits marker, [4] four digits marker, [5] five digits marker
Mass
-10 characters for net mass given in adjustment unit (with dot and a
floating-point “-“ sign )
Mass unit
-3 characters - left justification
Tare
-9 characters with dot - right justification (when floating-point tare
gets turned off automatically then zero value is sent)
Tare unit
-3 characters - left justification
Hidden digits quantity
-Number specifying quantity of hidden digits: [space] when no digits
are hidden, [1] when 1 digit is hidden
An example:
NT CR LF
- command sent from a computer
N T _ ? _ _ 0 _ _ _ _ _ - 5 . 1 1 3 _ g _
_ _ _ _ _ _ 0 . 0 0 0 _ g _ _ _0 CR LF
– command carried out, response: mass value and
remaining data
Where: _ - space
38.3. MANUAL PRINTOUT/AUTOMATIC PRINTOUT
4Y series balance enables generating manual or automatic printouts:
•
Manual printout: press
key on stabilization of indication (measurement result).
•
Automatic printout is generated automatically, in accordance to the settings of automatic
printout (
see section 14.5 of this user manual
).
The content of a printout depends on setting in menu <Standard printout> - <Weighing printout
template>(
see section 14.5 of this user manual)
.
Содержание UYA 4Y
Страница 8: ...8...
Страница 9: ...9 1 GENERAL INFORMATION 1 1 DIMENSIONS Ultra microbalances and microbalances...
Страница 10: ...10 MYB 4Y Microbalances Indicator XA 4Y series balances...
Страница 11: ...11 XA 4Y F series balances...
Страница 195: ...195...
Страница 196: ...196...