Security and Logins
4-11
9664-A2-GB20-00
March 2000
See
Configuring SNMP NMS Security Options
in Chapter 3,
Configuration, for
more information about SNMP NMS Security configuration options.
Creating a Login
A login is required if security is enabled.* Up to six login ID/password
combinations can be created using ASCII text, and each login must have a
specified access level. Logins must be unique and they are case-sensitive.
"
Procedure
To create a login record:
1. Select Administer Logins.
Main Menu
→
Control
→
Administer Logins
2. Select New, and set the following configuration options, as appropriate.
In the field . . .
Enter the . . .
Login ID
ID of 1 to 10 characters.
Password
Password from 1 to 10 characters.
Re-enter password
Password again to verify that you entered the
correct password into the device.
Access Level
Access level: 1, 2, or 3.
H
Level-1 – User can add, change, and
display configuration options, save, and
perform device testing.
H
Level-2 – User can monitor and perform
diagnostics, display status and
configuration option information.
H
Level-3 – User can only monitor and
display status and configuration screens.
CAUTION: Make sure at least one login is set
up for Level-1 access or you may be
inadvertently locked out.
NOTE:
See
Resetting the Unit and Restoring Communication
in Chapter 6,
Troubleshooting, should you be locked out inadvertently.
3. Save your changes.
When Save is complete, the cursor is repositioned at the Login ID field, ready
for another entry.
*
Security is enabled by the configuration options Login Required for the communication port, and Telnet Login
Required or FTP Login Required for a Telnet or FTP Session.
Содержание FrameSaver SLV 9664
Страница 1: ...FrameSaver SLV 9664 USER S GUIDE Document No 9664 A2 GB20 00 March 2000 ...
Страница 18: ...About the FrameSaver SLV 9664 1 6 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 28: ...User Interface and Basic Operation 2 10 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 130: ...Operation and Maintenance 5 36 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 150: ...Troubleshooting 6 20 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 182: ...Setting Up Network Health for FrameSaver Devices 9 10 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 186: ...Menu Hierarchy A 4 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 214: ...SNMP MIBs and Traps and RMON Alarm Defaults B 28 9664 A2 GB20 00 March 2000 This page intentionally left blank ...