Configuration
3-8
9664-A2-GB20-00
March 2000
Minimal Configuration Before Deploying Remote Units
At a minimum, the following configuration options must be set before deploying a
a FrameSaver unit to a remote site:
H
Node IP Address
H
Node Subnet Mask
See Table 3-9,
Node IP Options
, for a description of these options.
Entering System Information and
Setting the System Clock
Select System Information to set up or display the general SNMP name for the
unit, its location, and a contact for the unit, as well as to set the system clock.
Main Menu
→
Control
→
System Information
The following information is available for viewing. Save any entries or changes.
If the selection is . . .
Enter the . . .
Device Name
Unique name for device identification of up to 20 characters.
System Name
SNMP system name; can be up to 255 characters.
System Location
System’s physical location; can be up to 255 characters.
System Contact
Name and how to contact the system person; can be up to
255 characters.
Date
Current date in the month/day/year format (mm/dd/yyyy).
Time
Current time in
the hours:minutes format (hh:mm:ss).
NOTE:
To clear existing information, place the cursor in the Clear field ( Tab to the
Clear field ) and press Enter.
See Chapter 4,
Security and Logins
, to set up and administer logins.
Содержание FrameSaver SLV 9664
Страница 1: ...FrameSaver SLV 9664 USER S GUIDE Document No 9664 A2 GB20 00 March 2000 ...
Страница 18: ...About the FrameSaver SLV 9664 1 6 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 28: ...User Interface and Basic Operation 2 10 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 130: ...Operation and Maintenance 5 36 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 150: ...Troubleshooting 6 20 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 182: ...Setting Up Network Health for FrameSaver Devices 9 10 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 186: ...Menu Hierarchy A 4 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 214: ...SNMP MIBs and Traps and RMON Alarm Defaults B 28 9664 A2 GB20 00 March 2000 This page intentionally left blank ...