Health and Status Messages (2 of 2)
Message
What It Indicates
LMI Discovery in Progress,
frame relay link
2
Local Management Interface protocol discovery is
in progress to determine which protocol will be
used on the specified frame relay link.
LMI Down,
frame relay link
2
The Local Management Interface(s) has been
declared down for the specified frame relay link.
LOS at Network
1
A Loss of Signal (LOS) condition is detected on the
leased line network interface when it is not
transmitting INFO3 or receiving INFO4.
Network Com Link Down
The communication link for the COM port is down,
and the COM port is configured for Net Link.
SLV Timeout, DLCI
nnnn,
frame relay link
1, 2, 3
An excessive number of SLV communication
responses from the remote FrameSaver SLV unit
have been missed on the specified multiplexed
DLCI; the DLCI is not suitable for user data.
;
When a hardware bypass capable device has
been detected at the other end of the PVC and this
condition occurs, only user data for EDLCI 0 will be
transmitted while this condition exists.
Two Level-1 Users Accessing
Device
Two Level 1 users are already using the menu-
driven user interface; only two sessions can be
active at one time.
1
nnnn indicates a DLCI number of 16 through 1007.
2
frame relay link is one of the following:
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-1. The frame relay link associated with the user data port.
3
Does not apply to a TS Management Link DLCI.
Содержание FrameSaver SLV 9664
Страница 1: ...FrameSaver SLV 9664 USER S GUIDE Document No 9664 A2 GB20 00 March 2000 ...
Страница 18: ...About the FrameSaver SLV 9664 1 6 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 28: ...User Interface and Basic Operation 2 10 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 130: ...Operation and Maintenance 5 36 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 150: ...Troubleshooting 6 20 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 182: ...Setting Up Network Health for FrameSaver Devices 9 10 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 186: ...Menu Hierarchy A 4 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 214: ...SNMP MIBs and Traps and RMON Alarm Defaults B 28 9664 A2 GB20 00 March 2000 This page intentionally left blank ...