Configuration
3-28
9664-A2-GB20-00
March 2000
Table 3-6.
Interface Frame Relay Options (3 of 3)
LMI Inbound Heartbeat (T2)
Possible Settings: 5, 10, 15, 20, 25, 30
Default Setting: 15
Configures the LMI-defined T2 parameter, which sets the number of seconds between
the receipt of status enquiry messages on the network side of the LMI. Applies to the
network side of a UNI only.
5 – 30 – Specifies the number of seconds between the receipt of status enquiry
messages in increments of 5.
LMI N4 Measurement Period (T3)
Possible Settings: 5, 10, 15, 20, 25, 30
Default Setting: 20
Configures the LMI-defined T3 parameter, which is the time interval (in seconds) that the
network side of the LMI uses to measure the maximum number of status enquiry
messages that have been received (N4) from the user side.
5 – 30 – Specifies the interval of time in increments of 5.
Manually Configuring DLCI Records
The Auto-Configuration feature automatically configures DLCI Records and their
PVC Connections. DLCI Records can also be created manually (see Table 3-7).
Main Menu
→
Configuration
→
[Network/Data Ports]
→
DLCI Records
Typically, DLCI Records only need to be configured when building Management
PVCs between the NOC and the central site unit; the unit automatically
configures non-management DLCI Records and PVC Connections.
Table 3-7.
DLCI Record Options (1 of 3)
DLCI Number
Possible Settings: 16 – 1007
Default Setting: Initially blank; no default.
Specifies the number for the DLCI in the DLCI record. The parameter determines which
DLCI record is used for transferring data on a particular frame relay interface. DLCI
numbers range from 0 to 1023. However, the numbers 0 – 15 and 1008 – 1023 are
reserved. Entry of an invalid number results in the error message
Value Out of
Range (16 – 1007)
. If the DLCI number is part of a connection, this field is read-only.
NOTES: – If a DLCI number is not entered, the DLCI record is not created.
– The DLCI number entered must be unique for the interface.
– Changing settings for this configuration option causes the FrameSaver
unit to abort any active frame relay tests.
16 – 1007 – Specifies the DLCI number.
Содержание FrameSaver SLV 9664
Страница 1: ...FrameSaver SLV 9664 USER S GUIDE Document No 9664 A2 GB20 00 March 2000 ...
Страница 18: ...About the FrameSaver SLV 9664 1 6 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 28: ...User Interface and Basic Operation 2 10 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 130: ...Operation and Maintenance 5 36 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 150: ...Troubleshooting 6 20 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 182: ...Setting Up Network Health for FrameSaver Devices 9 10 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 186: ...Menu Hierarchy A 4 9664 A2 GB20 00 March 2000 This page intentionally left blank ...
Страница 214: ...SNMP MIBs and Traps and RMON Alarm Defaults B 28 9664 A2 GB20 00 March 2000 This page intentionally left blank ...