Search from Menu Tree
ZW-8000/7000/5000
User's Manual
219
7
Senso
r con
trol
ler
ope
ra
ti
ons
The grayed-out settings can only be used with ZW-8000
@
.
* default value
Setting
Option/Setting Range
Pages
I/O setting
[I/O]
Data output
setting
[COM.OUT]
Data output
destination
[OUTPUT]*
Off [OFF]*/Ethernet[ETN]/
RS232C[RS232C]
−
(cont'd)
Output data
format
[FORMAT]
ASCII[ASCII]*/Binary[BINARY]
−
Number of
integer digits
[INT.NUM]
1 / 2 / 3 / 4 /5*
−
Fractional
digits
[DEC.NUM]
0 / 1 / 2 / 3 / 4 / 5 / 6*
−
Leading zeros
suppressed
[ZEROSP]
Off* /On
−
Field
separator
[FIELD]
None [NO]*/Comma [COMMA]/
Tab [TAB]/Space [SPACE]/
CR[CR]/LF[LF]/CR+LF[CRLF]/
Semicolon [SEMICO]
−
Record
separator
[RECORD]
None [NO]*/Comma [COMMA]/
Tab [TAB]/Space [SPACE]/
CR[CR]/LF[LF]/CR+LF[CRLF]/
Semicolon [SEMICO]
−
Condition for
measurement state
[MS.CON]
Number of
Edge
[SFC.NUM]
0 surface [0EDGE]/1surface [1EDGE] / 2
surface[2EDGE] /3 surface [3EDGE/ 4
surface[4EDGE] /Edge 5 or more[5ED.OVR]
−
Condition for
number of Edge
[SFC.CON]
Equal to the specified number of
Edge[EQRL]/Greater than the specified
number of Edge[GRT.THN]/ Less than the
specified number of Edge[LES.THN]
−
Bank setting
[BANK]
Bank change
[BK.CHG]
Bank number
[BANK]
Bank1 [BANK1] to Bank8 [BANK8]
(default value: Bank1) Up to Bank32
can be selected when the bank mode
is “Judgment value”.
Bank mode
[BK.MODE]
Bank mode
[BK.MODE]
Normal [NORMAL]*/
Judgment value [JUDGE]
Bank copy
[BK.COPY]
Copy source
[FROM]
Bank1 [BANK1] to Bank8 [BANK8]
Copy destination
[TO]
Bank1 [BANK1] to Bank8 [BANK8]
Bank clear
[BK.CLR]
Bank clear
[BK.CLR]
Ok [OK]/Cancel [CAN]
System
setting
[SYSTEM]
Sensor head
Calibration
[H.CALIB]
Sensor head
calibration
[H.CALIB]
OK [OK]/Cancel [CAN]
Save
[SAVE]
Save
[SAVE]
OK [OK]/Cancel [CAN]
Initialization
[INIT]
Initialization
[INIT]
OK [OK]/Cancel [CAN]
Synchronous
measurement
mode
[TRIGER]
Synchronous
measurement
mode
[TRIGER]
Internal synchronous measurement mode
[AUTO]* /External synchronous measurement
mode [PARA.IN] /PDO synchronous
measurement mode [ECT.PDO]
Extension fiber
cable length
[CABLE]
Extension fiber
cable length
[CABLE]
NONE [NONE]*/2m[2M]/
5m[5M]/10m[10M]/
20m[20M]/30m[30M]
Internal logging
setting
[LOGING]
Save interval
[INTRVL]
0 to 1000 (default value: 1)
Save count
[COUNT]
0 to 999999 (default value: 100000)
Output data format
[FORMAT]
ASCII [ASCII]*/ Binary [BINARY]
Overwrite mode
[OVR.WRT]
Off [OFF]*/On [ON]
Label insert mode
[LABEL]
Off [OFF]*/On [ON]
Содержание ZW-7000 Series
Страница 22: ...20 ZW 8000 7000 5000 User s Manual Index 329 Revision History 332 ...
Страница 23: ...ZW 8000 7000 5000 User s Manual 1 21 ...
Страница 54: ...Basic Operations for Displaying Measurement Results 52 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 96: ...Saving a project 94 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 192: ...Saving The Settings 190 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 280: ...Connecting by No protocol Communications 278 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 281: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 280 8 2 Troubleshooting 282 ...
Страница 288: ...Troubleshooting 286 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 289: ...9 APPENDICES APPENDICES 9 1 Specifications and External Dimensions 288 9 2 Laser safety 323 9 3 Firmware Update 324 ...
Страница 330: ...Firmware Update 328 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 333: ...Index ZW 8000 7000 5000 User s Manual 331 9 APPENDICES ...
Страница 335: ......