![Omron ZW-7000 Series Скачать руководство пользователя страница 63](http://html1.mh-extra.com/html/omron/zw-7000-series/zw-7000-series_user-manual_742279063.webp)
Part Names and Functions
ZW-8000/7000/5000
User's Manual
2
In
sta
llatio
n
a
nd
Con
nection
s
61
●
Connectors/terminals
Rear view
Bottom view
No.
Names
Functions
21
RS-232C connector
Connect the RS-232C cable when you are connecting the system with a PLC or personal
computer through RS-232C.
For the RS-232C cable, please use the following exclusive products:
If you use a cable not included in the exclusive products, a false operation or breakdown
may result.
• For connecting to a PLC or programmable terminal: ZW-XPT2
• For connecting to a PC: ZW-XRS2
22
Ethernet connector
This connector is used to connect with a personal computer through Ethernet.
For Ethernet cable, use a commercially available cable which satisfies the following condi-
tions:
• Category: 5e, or higher and Length: 30m or shorter.
• RJ45 connector (8 pin registered jack)
• When connect 1:1: select Ethernet crossover cable.
• When connect by network HUB: select straight cable.
23
EtherCAT input connector
This connector is used to connect to EtherCAT-compatible devices.
Use the recommended EtherCAT cable.
24
EtherCAT input output connector This connector is used to connect to EtherCAT-compatible devices.
Use the recommended EtherCAT cable.
25
24 V input terminal block
This connector is used to connect to Sensor Controller 24 VDC power supply. The length
of Cables should be less than 30 m.
26
32-pole extension connector
• This connector connects the following output and input signals:
• Output signal:
Parallel I/Os, including output for judgment, ALARM, BUSY
ENABLE, Bank Number, SYNCFLG/TRIGBUSY, STABILITY,
LOGSTAT, LOGERR, TASKSTAT
• Input signal:
ZERO, RESET, TIMING, LIGHT OFF, LOGGING,
Bank Number, SYNC/TRIG
• Make sure to use the electric cable within 2m.
27
Analog output terminal block
This connector connects the output for analog voltage and analog current.
Use the electric cable within 2m.
28
Fiber adapter
The fiber adapter connects the fiber connector.
29
ROM connector
The ROM connector connects the Calibration ROM.
30
Frame ground terminal
This is the connector for frame ground. It connects grounding wire.
No.
Names
Functions
31
DIN track attachment hook
Used when fixing the Sensor Controller on DIN track.
No.
Names
Functions
32
Installation screw hole
Used when fixing the Sensor Controller with screws.
Содержание ZW-7000 Series
Страница 22: ...20 ZW 8000 7000 5000 User s Manual Index 329 Revision History 332 ...
Страница 23: ...ZW 8000 7000 5000 User s Manual 1 21 ...
Страница 54: ...Basic Operations for Displaying Measurement Results 52 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 96: ...Saving a project 94 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 192: ...Saving The Settings 190 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 280: ...Connecting by No protocol Communications 278 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 281: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 280 8 2 Troubleshooting 282 ...
Страница 288: ...Troubleshooting 286 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 289: ...9 APPENDICES APPENDICES 9 1 Specifications and External Dimensions 288 9 2 Laser safety 323 9 3 Firmware Update 324 ...
Страница 330: ...Firmware Update 328 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 333: ...Index ZW 8000 7000 5000 User s Manual 331 9 APPENDICES ...
Страница 335: ......