![Omron ZW-7000 Series Скачать руководство пользователя страница 106](http://html1.mh-extra.com/html/omron/zw-7000-series/zw-7000-series_user-manual_742279106.webp)
Displaying measured values in graphs
104
ZW-8000/7000/5000
User's Manual
3
Select data to monitor the trend for.
Set data to monitor the trend for.
The types of data that can be set are as follows.
4
Set the logging sampling interval.
Set the logging sampling interval for the target data.
* 1: The types of values that can be set vary depending on the measurement cycle being set.
Values outside the following range cannot be set.
0.5 [ms]/Measuring cycle [ms] to 100 [ms]/Measuring cycle [ms]
5
Click the Start icon (
) to start the sampling.
When the sampling starts, the sampled data is displayed in the graph.
6
Click the End icon (
) to end the sampling.
When the sampling ends, the graph display stops too.
Item
Setting item
Description
Target data
OUT1
Measurement results assigned to OUT1
OUT2
Measurement results assigned to OUT2
OUT3
Measurement results assigned to OUT3
OUT4
Measurement results assigned to OUT4
TIMING
TIMING input signal (parallel I/O)
ZERO
ZERO input signal (parallel I/O)
BUSY
BUSY output signal (parallel I/O)
ENABLE
ENABLE output signal (parallel I/O)
HIGH
HIGH output signal (parallel I/O)
PASS
PASS output signal (parallel I/O)
LOW
LOW output signal (parallel I/O)
TASKSTAT
TASKSTAT output signal (parallel I/O)
LOGGING
LOGGING input signal (parallel I/O)
LOGSTAT
LOGSTAT output signal (parallel I/O)
LOGERR
LOGERR output signal (parallel I/O)
STABILITY
STABILITY output signal (parallel I/O)
RESET
RESET output signal (ParallelI/O)
LIGHT_OFF
LIGHT_OFF input signal (parallel I/O)
BUFFER_ERR
Turn ON when dropping occurs.
Dropping may occur depending on the load factor of PC when acquiring
data from ZW-8000/7000/5000 series. If dropping occurs, increase the
arguments of logging.
Item
Setting item
Range
Description
Sampling setting
Logging sampling interval * 1
Set the sampling interval for the target data.
You can also specify the timing (start trigger, end trigger) for the graph display.
Note
Содержание ZW-7000 Series
Страница 22: ...20 ZW 8000 7000 5000 User s Manual Index 329 Revision History 332 ...
Страница 23: ...ZW 8000 7000 5000 User s Manual 1 21 ...
Страница 54: ...Basic Operations for Displaying Measurement Results 52 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 96: ...Saving a project 94 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 192: ...Saving The Settings 190 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 280: ...Connecting by No protocol Communications 278 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 281: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 280 8 2 Troubleshooting 282 ...
Страница 288: ...Troubleshooting 286 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 289: ...9 APPENDICES APPENDICES 9 1 Specifications and External Dimensions 288 9 2 Laser safety 323 9 3 Firmware Update 324 ...
Страница 330: ...Firmware Update 328 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 333: ...Index ZW 8000 7000 5000 User s Manual 331 9 APPENDICES ...
Страница 335: ......