Class
Name
Description
Parallel
output
HIGH output
This outputs judgment results - HIGH (HIGH threshold values < Measured value).
PASS output
This outputs judgment results - PASS (LOW threshold values
≤
Measured value
≤
HIGH
threshold values).
LOW output
This outputs judgment results - LOW (LOW threshold values > Measured value).
ALARM output
This turns ON when there is a system error.
BUSY output
This turns ON during sampling with the hold function enabled. It allows you to check
whether or not the self-trigger is functioning correctly.
It also turns ON during bank switching.
ENABLE output
This turns ON when the sensor is ready for measurement.
This output is interlocked with the ENABLE indicator.
BANK_OUT output
This outputs the currently specified bank number.
It expresses the bank number in combinations of BANK_OUT1, 2 and 3.
SYNCFLG/TRIGBUSY
output
In the internal/PDO synchronized mode, this output operates as SYNCFLG. This turns ON
when measurement synchronization processing is executed by SYNC input and the state
changes to one where normal measurement values can be output.
In the external synchronous measurement mode, this output operates as TRIGBUSY. This
turns ON while a measurement by TRIG input is being performed. The next TRIG input
cannot be turned ON until this turns OFF.
STABILITY output
This turns ON when 1surface is within the measurement range.
This output is interlocked with the STABILITY indicator.
LOGSTAT output
This turns ON while internal logging is in execution.
LOGERR output
This turns ON when internal logging fails. Turns ON when the maximum number of logging
results are saved and you try to execute internal logging. If the LOGGING signal turns OFF,
LOGERR signal is also turned OFF.
TASKSTAT output
This turns ON when the measurement value is finalized.
In FUNC mode, output of each signals are the followings;
• BUSY output Turns ON
BANK_OUT Outputs the current bank number
Other signals Turns OFF
Bank Number BANK_OUT1
BANK_OUT2
BANK_OUT3
BANK1
OFF
OFF
OFF
BANK2
ON
OFF
OFF
BANK3
OFF
ON
OFF
BANK4
ON
ON
OFF
BANK5
OFF
OFF
ON
BANK6
ON
OFF
ON
BANK7
OFF
ON
ON
BANK8
ON
ON
ON
Содержание ZW-7000 Series
Страница 22: ...20 ZW 8000 7000 5000 User s Manual Index 329 Revision History 332 ...
Страница 23: ...ZW 8000 7000 5000 User s Manual 1 21 ...
Страница 54: ...Basic Operations for Displaying Measurement Results 52 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 96: ...Saving a project 94 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 192: ...Saving The Settings 190 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 280: ...Connecting by No protocol Communications 278 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 281: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 280 8 2 Troubleshooting 282 ...
Страница 288: ...Troubleshooting 286 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 289: ...9 APPENDICES APPENDICES 9 1 Specifications and External Dimensions 288 9 2 Laser safety 323 9 3 Firmware Update 324 ...
Страница 330: ...Firmware Update 328 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 333: ...Index ZW 8000 7000 5000 User s Manual 331 9 APPENDICES ...
Страница 335: ......