![Omron ZW-7000 Series Скачать руководство пользователя страница 217](http://html1.mh-extra.com/html/omron/zw-7000-series/zw-7000-series_user-manual_742279217.webp)
Search from Menu Tree
ZW-8000/7000/5000
User's Manual
215
7
Senso
r con
trol
ler
ope
ra
ti
ons
The grayed-out settings can only be used with ZW-8000
@
.
* default value
Setting
Option/Setting Range
Pages
Measurement
setting
[MEAS]
TASK1
[TASK1]
Threshold
[JUDGE]
Teaching
[TEACH]
High
threshold
[H.JUDGE]
-999.999999 to 999.999999 mm
(default value: +25% of measuring
range)
(cont'd)
(cont'd)
Low threshold
[L.JUDGE]
-999.999999 to 999.999999 mm
(default value: -25% of measuring
range)
Direct
[DIRECT]
High
threshold
[H.JUDGE]
-999.999999 to 999.999999 mm
(default value: +25% of measuring
range)
Low threshold
[L.JUDGE]
-999.999999 to 999.999999 mm
(default value: -25% of measuring
range)
TASK2
[TASK2]
(Same content as TASK1)
Default value of measurement item is [NONE]
TASK3
[TASK3]
(Same content as TASK1)
Default value of measurement item is [NONE]
TASK4
[TASK4]
(Same content as TASK1)
Default value of measurement item is [NONE]
I/O setting
[I/O]
Non-measurement
setting
[HLD.RST]
Non-measurement
setting
[HLD.RST]
Keep [KEEP]/Clamp [CLAMP]*4
*1
Keep count
specification
flag
[KEEP.EN]
OFF[OFF]/ON[ON]*
*1
Keep count
[KEEP.CN]
1 to 16382
(default value: 8)
*1
Number of
restorations
[RESR.CN]
1 to 16382
(default value: 1
)
*1
Non-Measuring
Specification
[CLP.CON]
−
*1
Number of
Edge
[SFC.NUM]
ON[ON]/OFF[OFF]
*
*1
Reflection
power
[REF.POW]
ON[ON]/OFF[OFF]*
*1
TIMING
input mode
[TIM.MOD]
TIMING
input mode
[TIM.MOD]
Specify timing to measure[MEAS]*/
Specify timing to exposure[EXPOSE] *1
Judgment
[JUDGE]
Output target
[OUTPUT]
Output target
[OUTPUT]
TASK1 [TASK1]*/TASK2 [TASK2]/
TASK3 [TASK3]/TASK4 [TASK4]
*1
Hysteresis
[HYS]
Hysteresis
[HYS]
0 to 99.9999 mm
(default value: 0.05% of measuring
range)
*1
Timer
[TIMER]
TIMER
*2
[TIMER]
Off* [OFF]/Off delay [OFF.DLY]/
On delay [ONDLY]/One shot [1SHOT]
*1
Timer time
*3
[TIME]
0.2 to 5000 ms (default value: 0.2)
*1. For more detail, refer to the following.
“6-1 Connecting Parallel I/O” described in Displacement Sensor ZW-8000/7000/5000 series Confocal Fiber Type
Displacement Sensor User’s Manual for Communications Settings (Z363)
*2. Only [OFF] is allowable in External/PDO synchronized mode.
*3. First enter the number and set the decimal point.
*4. KEEP is the initial value for ZW-8000 and CLAMP is the initial value for ZW-7000/5000.
Содержание ZW-7000 Series
Страница 22: ...20 ZW 8000 7000 5000 User s Manual Index 329 Revision History 332 ...
Страница 23: ...ZW 8000 7000 5000 User s Manual 1 21 ...
Страница 54: ...Basic Operations for Displaying Measurement Results 52 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 96: ...Saving a project 94 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 192: ...Saving The Settings 190 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 280: ...Connecting by No protocol Communications 278 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 281: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 280 8 2 Troubleshooting 282 ...
Страница 288: ...Troubleshooting 286 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 289: ...9 APPENDICES APPENDICES 9 1 Specifications and External Dimensions 288 9 2 Laser safety 323 9 3 Firmware Update 324 ...
Страница 330: ...Firmware Update 328 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 333: ...Index ZW 8000 7000 5000 User s Manual 331 9 APPENDICES ...
Страница 335: ......