Setting the Output Conditions
ZW-8000/7000/5000
User's Manual
165
4
Settin
gs for Function
●
Setting TIMING input mode
If you select External input as the trigger method, set the TIMING input mode. The data sampled when TIMING
input is turned ON varies with each TIMING input mode.
Multi View Explore
: [Bank Group] | [(Bank Data Name)] (double click)
→
Edit pane
: [IO Settings] icon (
)
→
IO Settings window
: [Control input]
Setting item Setting value
Description
TIMING
input mode
Specify timing to
measure
The data of which measurement has been completed while TIMING input was ON is sampled. The
time from TIMING input to measurement value output is shorter compared to "Specify timing to
exposure" mode, this is suitable for performing height measurements with the Sensor Head and
measurement target in a resting state.
Specify timing to
exposure
The data of which exposure has been completed while TIMING input was ON is sampled. Since
measurement values of the intended locations on the measurement target can be obtained with
TIMING input, this is suitable for performing shape measurements while moving the Sensor Head or
measurement target.
1
Set the TIMING input mode.
Expo
su
re (1)
Expo
su
re
proce
ss
TIMING inp
u
t
s
ign
a
l
Ex
a
mple of when the Hold mode i
s
s
et to
sa
mple
OFF
ON
Intern
a
l
proce
ss
of the
s
en
s
or
O
u
tp
u
t me
asu
ring v
a
l
u
e
Expo
su
re (2)
Expo
su
re (
3
)
Expo
su
re (4)
Expo
su
re (5)
Expo
su
re (6)
Me
asu
rement (0)
Me
asu
ring
proce
ss
Me
asu
rement (1) Me
asu
rement (2) Me
asu
rement (
3
) Me
asu
rement (4) Me
asu
rement (5)
O
u
tp
u
t
roce
ss
O
u
tp
u
t (2)
Expo
su
re (1)
Expo
su
re
proce
ss
TIMING inp
u
t
s
ign
a
l
Ex
a
mple of when the Hold mode i
s
s
et to
sa
mple
OFF
ON
Intern
a
l
proce
ss
of the
s
en
s
or
O
u
tp
u
t
me
asu
ring
v
a
l
u
e
Expo
su
re (2)
Expo
su
re (
3
)
Expo
su
re (4)
Expo
su
re (5)
Expo
su
re (6)
Me
asu
rement (0)
Me
asu
ring
proce
ss
Me
asu
rement (1) Me
asu
rement (2) Me
asu
rement (
3
) Me
asu
rement (4) Me
asu
rement (5)
O
u
tp
u
t
proce
ss
O
u
tp
u
t (4)
Содержание ZW-7000 Series
Страница 22: ...20 ZW 8000 7000 5000 User s Manual Index 329 Revision History 332 ...
Страница 23: ...ZW 8000 7000 5000 User s Manual 1 21 ...
Страница 54: ...Basic Operations for Displaying Measurement Results 52 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 96: ...Saving a project 94 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 192: ...Saving The Settings 190 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 280: ...Connecting by No protocol Communications 278 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 281: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 280 8 2 Troubleshooting 282 ...
Страница 288: ...Troubleshooting 286 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 289: ...9 APPENDICES APPENDICES 9 1 Specifications and External Dimensions 288 9 2 Laser safety 323 9 3 Firmware Update 324 ...
Страница 330: ...Firmware Update 328 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 333: ...Index ZW 8000 7000 5000 User s Manual 331 9 APPENDICES ...
Страница 335: ......