Setting the Output Conditions
148
ZW-8000/7000/5000
User's Manual
Multi-point scaling
With ZW-8000
@
, measurements are taken at multiple locations and a precision stage is used to minimize the
measurement error between the measurement value and the actual distance.
This function is enabled when nonlinearity occurs in the measurement error of the measurement value and the
actual distance.
This function cannot be used with ZW-7000
@
/ZW-5000
@
.
Example: When correcting measurement values to match actual distances at 4 points
Separate each distance between the N specified points by at least 1% of the rated measuring range for the connected
Sensor Head.
For example, for the ZW-S8010, the two measured points must be separated by at least 1 mm × 0.01 = 0.01 mm as
the measuring range is 1 mm (± 0.5 mm).
Item
Setting item
Setting value
Description
Scaling
(Multi-point
scaling)
Scaling points
(n)
2 to 10 [point]
Set the points on which to execute scaling.
Set value (1st
point)
-999.999999 to 999.999999 [mm]
Correct the measured value of Point1, and set the ideal
value to display.
Set value (Point2
to Point(n-1))
-999.999999 to 999.999999 [mm]
Correct the measured value of Point2 to Point(n-1), and set
the ideal value to display
Measurement
value (Point(n))
-999.999999 to 999.999999 [mm]
Correct the measured value of Point(n), and set the ideal
value to display.
Act
ua
l di
s
t
a
nce
s
(mm)
Me
asu
red v
a
l
u
e
(mm)
Important
Содержание ZW-7000 Series
Страница 22: ...20 ZW 8000 7000 5000 User s Manual Index 329 Revision History 332 ...
Страница 23: ...ZW 8000 7000 5000 User s Manual 1 21 ...
Страница 54: ...Basic Operations for Displaying Measurement Results 52 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 96: ...Saving a project 94 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 192: ...Saving The Settings 190 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 280: ...Connecting by No protocol Communications 278 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 281: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 280 8 2 Troubleshooting 282 ...
Страница 288: ...Troubleshooting 286 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 289: ...9 APPENDICES APPENDICES 9 1 Specifications and External Dimensions 288 9 2 Laser safety 323 9 3 Firmware Update 324 ...
Страница 330: ...Firmware Update 328 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 333: ...Index ZW 8000 7000 5000 User s Manual 331 9 APPENDICES ...
Страница 335: ......