Specifications and External Dimensions
ZW-8000/7000/5000
User's Manual
309
9
APPE
NDICE
S
The Export Trade Control Order compatible Sensor controller (ZW-8000T/7000T/5000T) is available.
When using this Sensor Controller, the minimum resolution is 0.25
μ
m regardless of the connected Sensor Head and setting conditions.
*1:
When an extension fiber cable of 2 m or longer (on the ZW-8000 series), 10 m or longer (on the ZW-7000 series) or 5 m or longer (on the
ZW-5000 series) is connected, the setting range of the measurement cycle (exposure time) changes. For details, refer to "Setting the Mea-
surement Cycle" p.122 of this manual.
Main
functions
Exposure time
Automatic/Fixed
Measuring cycle
*1
60
μ
s to 7,500
μ
s
20
μ
s to 400
μ
s
80 µs to 1,600 µs
Material setting
Standard/Mirror/Rough surfaces
Measurement item
Height/Thickness of transparent object/Calculation
Filtering
Median/Average/Differentiation/High pass/Low pass/Band pass
Output
Scaling/Different holds/Zero reset/Logging for a measured value/Keep, Clamp
Display
Measured value/Threshold value/Analog output voltage or current value/
Judgment result/Resolution/Light power/Internal logging condition
/Peak amount of received light
Number of configurable banks
NORMAL mode: Max. 8 banks
JUDGMENT mode: Max. 32 banks
Task process
Multi-task (up to 4 tasks per bank)
System
Save/Initialization/Display measured information/Communication settings/Sensor
head calibration/Key-lock/Zero reset memory/Timing input
Rating
Power supply voltage
21.6 to 26.4 VDC (including ripple)
Current consumption
700 mA or less
800 mA or less
Insulation resistance
Across all lead wires and FG terminal: 20 M
Ω
(by 250 VDC)
Dielectric strength
Between all lead wires and FG terminal: 500 VAC, 50/60 Hz, 1 minute
Environmen-
tal resistance
Degree of protection
IP20 (IEC60529)
Vibration resistance (destructive)
10 to 55 Hz (half amplitude 0.35 mm), 50 mins in each of X/Y/Z directions
Shock resistance (destructive)
150 m/s
2
, 6 direction, 3 times each (up/down, left/right, forward/backward)
Ambient temperature range
Operation: 0 to 40
°
C, Storage: -15 to +60
°
C
(No freezing and condensation)
Ambient humidity range
Operation/storage: 35 to 85% (No condensation)
Grounding
D-type grounding (grounding resistance of 100
Ω
or less)
Note: For conventional Class D grounding
Material
Chassis: PC
Weight
Approx. 950g (main unit
only), Approx. 150 g
(Parallel cable)
Approx. 900g (main unit only), Approx. 150 g (Parallel
cable)
Accessories
Parallel cable (ZW-XCP2E)
10 Fiber cleaners (ZW-XCL)
Instruction Manual
Member registration sheet
Precautions
Parallel cable (ZW-
XCP2E)
10 Fiber cleaners (ZW-
XCL)
Fiber adapter cap
Strap
Instruction Manual
Member requistration
sheet
Precautions
Item
Specifications
ZW-8000
@
ZW-7000
@
ZW-5000
@
Содержание ZW-7000 Series
Страница 22: ...20 ZW 8000 7000 5000 User s Manual Index 329 Revision History 332 ...
Страница 23: ...ZW 8000 7000 5000 User s Manual 1 21 ...
Страница 54: ...Basic Operations for Displaying Measurement Results 52 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 96: ...Saving a project 94 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 192: ...Saving The Settings 190 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 280: ...Connecting by No protocol Communications 278 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 281: ...8 Troubleshooting Troubleshooting 8 1 Error Messages 280 8 2 Troubleshooting 282 ...
Страница 288: ...Troubleshooting 286 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 289: ...9 APPENDICES APPENDICES 9 1 Specifications and External Dimensions 288 9 2 Laser safety 323 9 3 Firmware Update 324 ...
Страница 330: ...Firmware Update 328 ZW 8000 7000 5000 User s Manual MEMO ...
Страница 333: ...Index ZW 8000 7000 5000 User s Manual 331 9 APPENDICES ...
Страница 335: ......