Sysmac device feature
OMRON EtherCAT master
EtherCAT master from
another manufacturer
NJ/NX-series CPU Unit
NX701-
££££
NX102-
££££
NX1P2-
£££££££
NJ501-
££££
NJ301-
££££
NJ101-
££££
CJ-series Position Con-
trol Unit
CJ1W-NC
£
8
£
Saving node address
settings
Supported.
Supported.
Partially supported.
Verifying the EtherCAT
network configuration
Supported.
Not supported.
Partially supported.
*1.
Errors are notified with emergency messages.
*2.
EtherCAT slaves for which data can be backed up have specific precautions. Refer to
EtherCAT Slaves for
Which You Can Back Up Data
in the
NJ/NX-series CPU Unit Software User's Manual (Cat. No. W501)
for
details on the precautions.
*3.
You cannot specify data to back up and restore.
*4.
Available backup and restore functions depend on the EtherCAT master from another manufacturer that you
use.
*5.
The node address setting method depends on the EtherCAT master from another manufacturer that you
use.
*6.
Whether the serial number can be checked or not depends on the EtherCAT master from another manufac-
turer that you use.
OMRON Slaves That Do Not Support Sysmac Devices
Sysmac device feature
OMRON EtherCAT master
EtherCAT master from
another manufacturer
NJ/NX-series CPU Unit
NX701-
££££
NX102-
££££
NX1P2-
£££££££
NJ501-
££££
NJ301-
££££
NJ101-
££££
CJ-series Position Con-
trol Unit
CJ1W-NC
£
8
£
Troubleshooting
Backing up and restor-
ing parameters
Supported.
Partially supported.
Partially supported.
Saving node address
settings
Partially supported.
Partially supported.
Partially supported.
Verifying the EtherCAT
network configuration
Not supported.
Not supported.
Partially supported.
*1.
Errors are notified with emergency messages.
*2.
EtherCAT slaves for which data can be backed up have specific precautions. Refer to
EtherCAT Slaves for
Which You Can Back Up Data
in the
NJ/NX-series CPU Unit Software User's Manual (Cat. No. W501)
for
details on the precautions.
*3.
You cannot specify data to back up and restore.
*4.
Available backup and restore functions depend on the EtherCAT master from another manufacturer that you
use.
*5.
Setting is possible on the node address switches. Node addresses set with the software cannot be stored in
the slave.
*6.
The node address setting method depends on the EtherCAT master from another manufacturer that you
use.
2 Part Names and Slave Settings
2-16
NJ/NX-series CPU Unit Built-in EtherCAT Port User's Manual (W505)
Содержание NJ101-10 Series
Страница 10: ...Manual Structure 8 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505...
Страница 68: ...2 Part Names and Slave Settings 2 18 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505...
Страница 80: ...3 EtherCAT Communications 3 12 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505...
Страница 236: ...9 Troubleshooting 9 38 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505...
Страница 274: ...Appendices A 38 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505...
Страница 275: ...I Index I 1 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505 I...