Item
Description
Project unit version
Version earlier than 1.40
Version 1.40 or later
Operation when more
than the maximum num-
ber of slaves are connect-
ed during communica-
tions
•
A
Network Configuration Error
(84210000 hex) event occurs.
•
Communications continue with
salves that are during commu-
nications.
•
A
Network Configuration
Verification Error (Unnecessary
Slave Connected)
(84320003 hex)
event occurs.
•
Communications continue with sal-
ves that are during communica-
tions. However, an error may occur
in synced slaves.
Event that will occur
Refer to
Correspondence of Events between Project Unit Version Earlier
than 1.40 and Project Unit Version 1.40 or Later
in the appendices of the
NJ/NX-series Troubleshooting Manual (Cat. No. W503)
for specific events.
Appendices
A-37
NJ/NX-series CPU Unit Built-in EtherCAT Port User's Manual (W505)
A-6
V
ersion Information
A
A-6-2 Dif
ferences between Project Unit V
ersion Earlier Than 1.40 and Project Unit V
ersion 1.40 or Later
Содержание NJ101-10 Series
Страница 10: ...Manual Structure 8 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505...
Страница 68: ...2 Part Names and Slave Settings 2 18 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505...
Страница 80: ...3 EtherCAT Communications 3 12 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505...
Страница 236: ...9 Troubleshooting 9 38 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505...
Страница 274: ...Appendices A 38 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505...
Страница 275: ...I Index I 1 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505 I...
Страница 279: ......