Variable name
Meaning
Function
Data type
Range of
values
Reference
_EC_StatisticsLog-
CycleSec
(Ver.1.11)
Diagnosis/Statistics
Log Cycle
Specifies the interval to write the diag-
nostic and statistical information of the di-
agnosis/statistics log in units of seconds.
When 0 is specified, the diagnostic and
statistical information is written only once
when the diagnosis/statistics log is
ended.
Note
The write interval does not
change even if you change the
value of this system-defined
variable while the diagnosis/
statistics log operation is in
progress.
UINT
0, or 30 to
1800
_EC_Statistic-
sLogBusy
(Ver.1.11)
Diagnosis/Statistics
Log Busy
TRUE while the diagnosis/statistics log
operation is in progress.
BOOL
TRUE or
FALSE
_EC_StatisticsLogErr
(Ver.1.11)
Diagnosis/Statistics
Log Error
TRUE when the diagnosis/statistics log
failed to start or it is impossible to write
into the log.
The value of this flag is determined when
_EC_StatisticsLogBusy
(Diagnosis/
Statistics Log Busy) changes to FALSE
after the diagnosis/statistics log operation
is started.
The error end is caused by the following.
•
Another records cannot be added in
the log file because the capacity of the
SD Memory Card is fully used.
•
The SD Memory Card is write-protect-
ed.
•
There is no SD Memory Card.
•
The function cannot be started be-
cause the value specified for
_EC_StatisticsLogCycleSec
(Diagno-
sis/Statistics Log Cycle) is invalid.
BOOL
TRUE or
FALSE
Meanings of Error Status Bits
The meanings of the individual bits in the following error status are the same.
•
_ErrSta
(Controller Error Status)
•
_PLC_ErrSta
(PLC Function Module Error Status)
•
_CJB_ErrSta
(I/O Bus Error Status)
•
_CJB_MstrErrSta
(I/O Bus Master Error Status)
•
_CJB_UnitErrSta
(I/O Bus Unit Error Status)
•
_NXB_ErrSta
(NX Bus Function Module Error Status)
•
_NXB_MstrErrSta
(NX Bus Function Module Master Error Status)
•
_NXB_UnitErrStaTbl
(NX Bus Function Module Unit Error Status)
•
_MC_ErrSta
(MC Error Status)
•
_MC_ComErrSta
(MC Common Error Status)
•
_MC_AX_ErrSta
(Axis Error Status)
•
_MC_GRP_ErrSta
(Axes Group Error Status)
•
_EC_ErrSta
(Built-in EtherCAT Error)
•
_EC_PortErr
(Communications Port Error)
•
_EC_MstrErr
(Master Error)
7 System-defined Variables Related to the Built-in EtherCAT Port
7-8
NJ/NX-series CPU Unit Built-in EtherCAT Port User's Manual (W505)
Содержание NJ101-10 Series
Страница 10: ...Manual Structure 8 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505...
Страница 68: ...2 Part Names and Slave Settings 2 18 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505...
Страница 80: ...3 EtherCAT Communications 3 12 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505...
Страница 236: ...9 Troubleshooting 9 38 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505...
Страница 274: ...Appendices A 38 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505...
Страница 275: ...I Index I 1 NJ NX series CPU Unit Built in EtherCAT Port User s Manual W505 I...
Страница 279: ......