Appendix B
Additional Origin Search Patterns
249
Reverse-mode Origin Searches 11
These origin searches are performed with an origin proximity switch and the initial search direction set to CW, but
no Z-phase signal.
Limit switches
Origin proximity
switch
Z-phase signal
Speed
Error
(Origin proximity and overtravel
simultaneously ON.)
Error
(Origin proximity and overtravel
simultaneously ON.)
Error (No origin proximity signal)
Error (No origin proximity signal)
Error (No origin proximity signal)
Error (No origin proximity signal)
CCW