Appendix B
Additional Origin Search Patterns
247
Reverse-mode Origin Searches 9
These origin searches are performed with an origin proximity switch and the initial search direction set to CW, but
no Z-phase signal.
Limit switches
Origin proximity
switch
Z-phase signal
Speed
Error
(Origin proximity and overtravel
simultaneously ON.)
Error
(Origin proximity and overtravel
simultaneously ON.)
Error
(Origin proximity and overtravel
simultaneously ON.)
Error
(Origin proximity and overtravel
simultaneously ON.)
Error
(Origin proximity and overtravel
simultaneously ON.)
Error
(Origin proximity and overtravel
simultaneously ON.)
CCW
CW
Содержание C200H-MC221 -
Страница 1: ...Cat No W315 E1 03 Motion Control Unit C200H MC221 OPERATION MANUAL ...
Страница 2: ......
Страница 3: ...C200H MC221 Motion Control Unit Operation Manual Details Revised June 2010 ...
Страница 4: ...iv ...
Страница 6: ...vi ...
Страница 10: ......
Страница 12: ......
Страница 16: ...xvi ...
Страница 42: ......
Страница 48: ......
Страница 196: ......
Страница 212: ......
Страница 242: ......
Страница 258: ......
Страница 304: ......