M0A21/M0A23 Series
May 06, 2022
Page
737
of 746
Rev 1.02
M0
A21
/M
0
A
2
3
SE
RIES
TEC
H
NICAL
RE
FEREN
C
E
M
ANUAL
Timer0 ~ Timer3 can generate trigger pules as PWM external clock source.
When the timer counter value matches the timer compared value or when the TMx_EXT pin edge
transition meets setting, timer can generate a trigger pulse by setting described in section 6.7.6.10.
The setting of PWM clock source is described in section 6.10.3.
From LIRC to Timer Capture Function
Measure the Time Interval of LIRC clock Speed
Set the timer capture source from LIRC clock and measure the time interval of the signal by using timer
capture function. The results of time interval can be used to trim LIRC through software.
The detailed setting of time capture function is described in section 6.7.6.8.
From Timer0/2 to Timer1/3
Inter-Timer Trigger Capture Mode
Timer0/2 will be forced in event counting mode, counting with external event, and will generate an
internal signal (INTR_TMR_TRG) to trigger Timer1/3 start or stop counting. The Timer1/3 will be forced
in capture mode and start/stop trigger-counting by Timer0/2 counter status.