A status flag that indicates the end of A/D conversion. Software can write 1 to clear this bit.
ADF bit is set to 1 at the following three conditions:
1.
When A/D conversion ends in Single mode.
2.
When A/D conversion ends on all specified channels in Single-cycle Scan mode and Continuous
Scan mode.
3.
When more than or equal to 8 samples in FIFO in Burst mode.