![Nuvoton NuMicro M0A21 Series Скачать руководство пользователя страница 289](http://html.mh-extra.com/html/nuvoton/numicro-m0a21-series/numicro-m0a21-series_technical-reference-manual_1720294289.webp)
M0A21/M0A23 Series
May 06, 2022
Page
289
of 746
Rev 1.02
M0
A21
/M
0
A
2
3
SE
RIES
TEC
H
NICAL
RE
FEREN
C
E
M
ANUAL
PDMA Time-out Period Counter Register 0 (PDMA_TOC0_1)
Register
Offset
R/W Description
Reset Value
PDMA_TOC0_1
P 0x440
R/W PDMA Time-out Counter Ch1 and Ch0 Register
0xFFFF_FFFF
31
30
29
28
27
26
25
24
TOC1
23
22
21
20
19
18
17
16
TOC1
15
14
13
12
11
10
9
8
TOC0
7
6
5
4
3
2
1
0
TOC0
Bits
Description
[31:16]
TOC1
Time-out Counter for Channel 1
This controls the period of time-out function for channel 1. The calculation unit is based on TOUTPSC1
(PDMA_TOUTPSC[6:4]) clock. For the example of time-out period, refer to TOC0 bit description.
[15:0]
TOC0
Time-out Counter for Channel 0
This controls the period of time-out function for channel 0. The calculation unit is based on TOUTPSC0
(PDMA_TOUTPSC[2:0]) clock. Time-out period = (Period of time-out clock) * (16-bit TOCn), n = 0,1.