y=2*x, z=y+1.
0 = Single-end analog input mode.
1 = Differential analog input mode.
Note:
In Differential Input mode, only the even number of the two corresponding channels needs to be
enabled in ADC_ ADCHER register. The conversion result will be placed to the corresponding data register
of the enabled channel.
Note:
The relation between Vplus and Vminus is Vplus + Vminus = Vref
[9]
PTEN
PDMA Transfer Enable Bit
When A/D conversion is completed, the converted data is loaded into ADDR0~16 ADDR26, ADDR27,
ADDR29, ADDR30. Software can enable this bit to generate a PDMA data transfer request.
0 = PDMA data transfer Disabled.
1 = PDMA data transfer in ADDR0~16, ADDR26, ADDR27, ADDR29, ADDR30 Enabled.
Note:
When PTEN=1, software must set ADIE=0 to disable interrupt.
[8]
TRGEN
External Trigger Enable Control
Enable or disable triggering of A/D conversion by external STADC pin, PWM trigger and Timer trigger. If
external trigger is enabled, the ADST bit can be set to 1 by the selected hardware trigger source.
0 = External trigger Disabled.
1 = External trigger Enabled.
Note:
The ADC external trigger function is only supported in Single-cycle Scan mode.
[7:6]
TRGCOND
External Trigger Condition
These two bits decide external pin STADC trigger event is level or edge. The signal must be kept at stable
state at least 8 PCLKs for level trigger and at least 4 PCLKs for edge trigger.
00 = Low level.
01 = High level.
10 = Falling edge.
11 = Rising edge.
[5:4]
TRGS
Hardware Trigger Source
00 = A/D conversion is started by external STADC pin.
01 = Timer0 ~ Timer3 overflow pulse trigger.
10 = Reserved.
11 = A/D conversion is started by PWM trigger.
Note:
Software should clear TRGEN bit and ADST bit to 0 before changing TRGS bits.
[3:2]
ADMD
A/D Converter Operation Mode Control
00 = Single conversion.
01 = Burst conversion.
10 = Single-cycle Scan.
11 = Continuous Scan.
Note 1:
When changing the operation mode, software should clear ADST bit first.
Note 2:
In Burst mode, the A/D result data is always at ADC Data Register 0.
[1]
ADIE
A/D Interrupt Enable Control
A/D conversion end interrupt request is generated if ADIE bit is set to 1.
0 = A/D interrupt function Disabled.
1 = A/D interrupt function Enabled.
[0]
ADEN
A/D Converter Enable Bit
0 = A/D converter Disabled.
1 = A/D converter Enabled.
Note:
Before starting A/D conversion function, this bit should be set to 1. Clear it to 0 to disable A/D converter
analog circuit to save power consumption.