Edge Detect
Brake Source
PWM_CH0
PWM_CH0 signals resume at next start
of PWM period after BRKEIF0 clear
BRKEIF1
BRKEIF0
s/w clear
BRKESTS0
BRKESTS1
s/w clear
PWM_CH1
PWM_CH1 signals resume at next start
of PWM period after BRKEIF1 clear
Note:
Output Brake State
Setting: BRKAEVEN = 3 (High)
BRKAODD = 2 (Low)
Figure 6.10-26 Edge Detector Waveform for PWMx_CH0 and PWMx_CH1 Pair
CNT
Level Detect
Brake Source
PWM_CH0
BRKLIF1
BRKLIF0
s/w clear
BRKLSTS0
BRKLSTS1
s/w clear
PWM_CH1
No matter BRKLIF0 or BRKLIF1 clear or not, while no brake
event occur, brake state resume at next start of PWM period
Note:
Output Brake State
Setting: BRKAEVEN = 3 (High)
BRKAODD = 2 (Low)
Figure 6.10-27 Level Detector Waveform for PWMx_CH0 and PWMx_CH1 Pair
The two kinds of detectors detect the same six brake sources: two from external input signals, two from
analog comparators(ACMP), and one from system fail, and one from software triggered, that are shown
in Figure 6.10-28. ACMP brake sources will be detected only when internal ACMP0_O or ACMP1_O
signal from low to high.
Among the above described brake sources, the brake source coming from system fail can still be