PWM Status Register (PWM_STATUS)
Register
Offset
R/W
Description
Reset Value
PWM_STATUS
0x120
R/W
PWM Status Register
0x0000_0000
31
30
29
28
27
26
25
24
Reserved
23
22
21
20
19
18
17
16
Reserved
ADCTRG5
ADCTRG4
ADCTRG3
ADCTRG2
ADCTRG1
ADCTRG0
15
14
13
12
11
10
9
8
Reserved
7
6
5
4
3
2
1
0
Reserved
CNTMAX4
Reserved
CNTMAX2
Reserved
CNTMAX0
Bits
Description
[31:22]
Reserved
Reserved.
[16+n]
n=0,1..5
ADCTRGn
ADC Start of Conversion Status
0 = Indicates no ADC start of conversion trigger event has occurred.
1 = An ADC start of conversion trigger event has occurred.
Note:
This bit can be cleared by software writing 1.
[15:5]
Reserved
Reserved.
[4]
CNTMAX4
Time-base Counter 4 Equal to 0xFFFF Latched Flag
0 = The time-base counter never reached its maximum value 0xFFFF.
1 = The time-base counter reached its maximum value.
Note:
This bit can be cleared by software writing 1.
[3]
Reserved
Reserved.
[2]
CNTMAX2
Time-base Counter 2 Equal to 0xFFFF Latched Flag
0 = indicates the time-base counter never reached its maximum value 0xFFFF.
1 = indicates the time-base counter reached its maximum value.
Note:
This bit can be cleared by software writing 1.
[1]
Reserved
Reserved.
[0]
CNTMAX0
Time-base Counter 0 Equal to 0xFFFF Latched Flag
0 = indicates the time-base counter never reached its maximum value 0xFFFF.
1 = indicates the time-base counter reached its maximum value.
Note:
This bit can be cleared by software writing 1.