User’s Manual U16896EJ2V0UD
654
CHAPTER 28 ELECTRICAL SPECIFICATIONS
Absolute Maximum Ratings (T
A
= 25
°
C) (1/2)
Parameter Symbol
Conditions
Ratings
Unit
V
DD
V
DD
= EV
DD
= AV
REF0
−
0.3 to +6.5
V
AV
REF0
V
DD
= EV
DD
= AV
REF0
−
0.3 to +6.5
V
EV
DD
V
DD
= EV
DD
= AV
REF0
−
0.3 to +6.5
V
V
SS
V
SS
= EV
SS
= AV
SS
−
0.3 to +0.3
V
AV
SS
V
SS
= EV
SS
= AV
SS
−
0.3 to +0.3
V
Supply voltage
EV
SS
V
SS
= EV
SS
= AV
SS
−
0.3 to +0.3
V
V
I1
P00 to P06, P30 to P35, P38, P39, P40 to P42,
P50 to P55, P90, P91, P96 to P99, P913 to P915,
PCM0, PCM1, PDL0 to PDL7, RESET, FLMD0
−
0.3 to EV
DD
+ 0.3
Note 1
V
Input voltage
V
I2
X1, X2, XT1, XT2
−
0.3 to V
DD
+ 0.3
Note 1
V
Analog input voltage
V
IAN
P70 to P77
−
0.3 to AV
REF0
+ 0.3
Note 1
V
Note 2
20 mA
P38, P39
Per pin
30 mA
P00 to P06, P30 to P35, P38, P39,
P40 to P42
35 mA
Output current, low
I
OL
P50 to P55, P90, P91, P96 to P99,
P913 to P915, PCM0, PCM1, PDL0
to PDL7
Total of all
pins:
70 mA
35 mA
Note 2
Per
pin
−
10 mA
P00 to P06, P30 to P35, P40 to P42
−
30 mA
Output current, high
I
OH
P50 to P55, P90, P91, P96 to P99,
P913 to P915, PCM0, PCM1, PDL0
to PDL7
Total of all
pins:
−
60 mA
−
30 mA
Normal operation mode
−
40 to +85
°
C
Operating ambient
temperature
T
A
Flash memory programming mode
−
40 to +85
°
C
μ
PD703302, 703302Y
−
65 to +150
°
C
Storage temperature
T
stg
μ
PD70F3302, 70F3302Y
−
40 to +125
°
C
Notes 1.
Be sure not to exceed the absolute maximum ratings (MAX. value) of each supply voltage.
2.
P00 to P06, P30 to P35, P40 to P42, P50 to P55, P90, P91, P96 to P99, P913 to P915, PCM0, PCM1,
PDL0 to PDL7
Cautions 1. Do not directly connect the output (or I/O) pins of IC products to each other, or to V
DD
, V
CC
, and
GND. Open-drain pins or open-collector pins, however, can be directly connected to each other.
Direct connection of the output pins between an IC product and an external circuit is possible, if
the output pins can be set to the high-impedance state and the output timing of the external
circuit is designed to avoid output conflict.
2. Product quality may suffer if the absolute maximum rating is exceeded even momentarily for
any parameter. That is, the absolute maximum ratings are rated values at which the product is
on the verge of suffering physical damage, and therefore the product must be used under
conditions that ensure that the absolute maximum ratings are not exceeded. The ratings and
conditions indicated for DC characteristics and AC characteristics represent the quality
assurance range during normal operation.
<R>