CHAPTER 6 16-BIT TIMER/EVENT COUNTER P (TMP)
User’s Manual U16896EJ2V0UD
219
(2) Operation timing in pulse width measurement mode
(a) Clearing overflow flag
The overflow flag can be cleared to 0 by clearing the TP0OVF bit to 0 with the CLR instruction and by
writing 8-bit data (bit 0 is 0) to the TP0OPT0 register. To accurately detect an overflow, read the TP0OVF
bit when it is 1, and then clear the overflow flag by using a bit manipulation instruction.
(i) Operation to write 0 (without conflict with setting)
(iii) Operation to clear to 0 (without conflict with setting)
(ii) Operation to write 0 (conflict with setting)
(iv) Operation to clear to 0 (conflict with setting)
0 write signal
Overflow
set signal
Register
access signal
Overflow flag
(TP0OVF bit)
Read
Write
0 write signal
Overflow
set signal
Register
access signal
Overflow flag
(TP0OVF bit)
Read
Write
0 write signal
Overflow
set signal
0 write signal
Overflow
set signal
Overflow flag
(TP0OVF bit)
Overflow flag
(TP0OVF bit)
L
H
L
To clear the overflow flag to 0, read the overflow flag to check if it is set to 1, and clear it with the CLR
instruction. If 0 is written to the overflow flag without checking if the flag is 1, the set information of
overflow may be erased by writing 0 ((ii) in the above chart). Therefore, software may judge that no
overflow has occurred even when an overflow actually has occurred.
If execution of the CLR instruction conflicts with occurrence of an overflow when the overflow flag is
cleared to 0 with the CLR instruction, the overflow flag remains set even after execution of the clear
instruction.