Troubleshooting 8-49
Problems with RAID System Configuration
Check the following if the server configuring a RAID System does not operate properly or a utility
does not operate correctly. If a relevant item is found, follow the processing method.
Fail to install the OS:
Is the RAID Controller configured?
→
Provide proper configuration for the RAID Controller by using the LSI Software
RAID Configuration Utility.
Fail to start the OS:
Is the BIOS of the RAID Controller changed?
→
Set the BIOS correctly by using the LSI Software RAID Configuration Utility.
Does POST recognize the RAID Controller?
→
After making sure that the RAID Controller is connected correctly, then power on
the server.
If the RAID Controller is not recognized correctly despite correct connection, the
RAID Controller may be failed. Contact your service representative.
Rebuild fails:
Is the capacity of the hard disk drive to be rebuilt sufficient?
→
The hard disk drive to be rebuilt should have the same capacity of the failed had
disk drive.
Is RAID0 configured?
→
RAID0 has no data redundancy, therefore, Rebuild is disabled in the RAID0
configuration. Replace the failed hard disk drive, create the configuration data
again and initialize the hard disk drives. Then recover the data by using backup
data.
Auto rebuild fails:
Was a sufficient time taken for hot swap of hard disk drives?
→
To allow the auto rebuild to operate correctly, it should take 90 seconds or longer
for the interval between the removal of the failed hard disk drive and the
installation of a new hard disk drive.
Is configuration correct?
→
Check the setting of auto rebuild by using the LSI Software RAID Configuration
Utility. <Menus to check: Top menu - [Objects] - [Adapter] - [Auto Rebuild]>
Содержание N8100-1668F
Страница 60: ...2 28 General Description This page is intentionally left blank ...
Страница 146: ...5 8 Installing the Operating System with Express Setup Flow of Setup ...
Страница 173: ...Installing the Operating System with Express Setup 5 35 Flow of Setup ...
Страница 242: ...5 104 Installing the Operating System with Express Setup This page is intentionally left blank ...
Страница 251: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 255: ...Installing and Using Utilities 6 13 Windows Server 2003 ...
Страница 282: ...7 14 Maintenance This page is intentionally left blank ...
Страница 287: ...Troubleshooting 8 5 With Redundant Power Supply Installed REAR LINK ACT lamp Speed lamp Speed lamp LINK ACT lamp ...
Страница 288: ...8 6 Troubleshooting With Non Redundant Power Supply Installed REAR Speed lamp LINK ACT lamp Speed lamp LINK ACT lamp ...
Страница 339: ...Troubleshooting 8 57 When you use a remote console 6 Each tool is selected and it starts ...
Страница 400: ...9 56 Upgrading Your Server 11 Bring down the lever to secure the CPU 12 Remove the protective cover from the heat sink ...
Страница 422: ...9 78 Upgrading Your Server This page is intentionally left blank ...
Страница 440: ...C 2 IRQ This page is intentionally left blank ...
Страница 464: ...D 24 Installing Windows Server 2008 R2 4 Activate Windows The Windows activation is complete ...
Страница 495: ...Installing Windows Server 2008 E 29 4 Activate Windows The Windows activation is complete ...
Страница 558: ...H 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Страница 568: ...I 10 Accessing Power and Performance Data This page is intentionally left blank ...
Страница 572: ...J 4 Product Configuration Record Table This page is intentionally left blank ...