Troubleshooting 8-39
Fail to start the OS with the /3GB switch
→
System often fails to start the OS with the /3GB switch.
In this case, please adjust the capacity of the user mode area using the /userva
switch in reference to the following URL.
http://support.microsoft.com/kb/316739/en
During installation, the following warning is registered in the System Log of the
Event Viewer:
Error detected on the device \Device\CdRom0
during the paging operation.
→
There is no problem on this issue.
Fail to start the OS:
Is a floppy disk in the floppy disk drive?
→
Take out the floppy disk and restart the server.
Is the NEC EXPRESSBUILDER DVD in the optical disk drive?
→
Take out the NEC EXPRESSBUILDER DVD and restart the server.
Is the OS broken?
→
Use recovery process to recover the system.
The OS presents unstable operation:
Did you update the system?
→
Installing a network drive after installation of the OS may cause unstable
operation. Use the NEC EXPRESSBUILDER DVD to update the system. (See
Chapter 6.)
The system does not restart automatically when a stop error occurs, though the
system is adjusted to automatically restarting:
→
When the system does not restart automatically, restart it manually.
The system restarts automatically when a stop error occurs, though the system is
NOT adjusted to automatically restarting:
→
There is no problem about this issue.
Check the System Event Log to confirm that STOP error occurred.
Содержание N8100-1668F
Страница 60: ...2 28 General Description This page is intentionally left blank ...
Страница 146: ...5 8 Installing the Operating System with Express Setup Flow of Setup ...
Страница 173: ...Installing the Operating System with Express Setup 5 35 Flow of Setup ...
Страница 242: ...5 104 Installing the Operating System with Express Setup This page is intentionally left blank ...
Страница 251: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 255: ...Installing and Using Utilities 6 13 Windows Server 2003 ...
Страница 282: ...7 14 Maintenance This page is intentionally left blank ...
Страница 287: ...Troubleshooting 8 5 With Redundant Power Supply Installed REAR LINK ACT lamp Speed lamp Speed lamp LINK ACT lamp ...
Страница 288: ...8 6 Troubleshooting With Non Redundant Power Supply Installed REAR Speed lamp LINK ACT lamp Speed lamp LINK ACT lamp ...
Страница 339: ...Troubleshooting 8 57 When you use a remote console 6 Each tool is selected and it starts ...
Страница 400: ...9 56 Upgrading Your Server 11 Bring down the lever to secure the CPU 12 Remove the protective cover from the heat sink ...
Страница 422: ...9 78 Upgrading Your Server This page is intentionally left blank ...
Страница 440: ...C 2 IRQ This page is intentionally left blank ...
Страница 464: ...D 24 Installing Windows Server 2008 R2 4 Activate Windows The Windows activation is complete ...
Страница 495: ...Installing Windows Server 2008 E 29 4 Activate Windows The Windows activation is complete ...
Страница 558: ...H 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank ...
Страница 568: ...I 10 Accessing Power and Performance Data This page is intentionally left blank ...
Страница 572: ...J 4 Product Configuration Record Table This page is intentionally left blank ...