11 - 26
MELSEC-Q
11 MANUAL CONTROL
11.4 Manual pulse generator operation
11.4.1 Outline of manual pulse generator operation
Important
Create the sequence program so that "
Cd.21
Manual pulse generator enable
flag" is always set to "0" (disabled) when a manual pulse generator operation is not
carried out.
Mistakenly touching the manual pulse generator when the manual pulse
generator enable flag is set to "1" (enable) can cause accidents or incorrect
positioning.
Manual pulse generator operation
In manual pulse generator operations, pulses are input to the QD75 from the
manual pulse generator. This causes the same No. of input pulses to be output
from the QD75 to the servo amplifier, and the workpiece is moved in the
designated direction.
The following shows an example of manual pulse generator operation.
1)
When the "
Cd.21
Manual pulse generator enable flag" is set to "1", the BUSY signal
turns ON and the manual pulse generator operation is enabled.
2)
The workpiece is moved corresponding to the No. of pulses input from the manual pulse
generator.
3)
The workpiece movement stops when no more pulses are input from the manual pulse
generator.
4)
When the "
Cd.21
Manual pulse generator enable flag" is set to "0", the BUSY signal
turns OFF and the manual pulse generator operation is disabled.
Manual pulse
generator
operation stops
t
BUSY signal [XC, XD, YE, XF]
Manual pulse
generator input
Start complete signal
[X10, X11, X12, X13]
Manual pulse generator operation enabled
0
OFF
ON
OFF
1) 2)
3)
4)
1
0
Cd. 21 Manual pulse
generator enable flag
1
2
[Precautions]
1 If the input from the manual pulse generator stops, the machine will decelerate to a stop within
90ms.
2 The start complete signal does not turn ON in manual pulse generator operation.
Fig. 11.16 Manual pulse generator operation
Содержание Melsec-Q QD75D1
Страница 1: ......
Страница 2: ......
Страница 22: ...A 20 MEMO ...
Страница 24: ...MEMO ...
Страница 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Страница 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Страница 292: ...MEMO ...
Страница 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Страница 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Страница 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Страница 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 693: ...Appendix 7 MELSEC Q APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse ...
Страница 699: ...Appendix 13 MELSEC Q APPENDICES Initial value Axis 1 Axis 2 Axis 3 Axis 4 Remarks 0 0 0 1 1 0 0 0 0 0 0 300 11 0 0 ...
Страница 836: ...Appendix 150 MELSEC Q APPENDICES Appendix 14 External dimension drawing 1 QD75P1N Unit mm 23 4 27 4 98 90 46 ...
Страница 837: ...Appendix 151 MELSEC Q APPENDICES 2 QD75P2N Unit mm 23 27 4 90 4 98 46 3 QD75P4N 23 27 4 90 4 98 46 Unit mm ...
Страница 838: ...Appendix 152 MELSEC Q APPENDICES 4 QD75D1N 12 90 23 27 4 Unit mm 98 4 46 5 QD75D2N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Страница 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Страница 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Страница 857: ......
Страница 858: ......