9 - 25
MELSEC-Q
9 MAJOR POSITIONING CONTROL
POINT
•
When the "reference axis speed" is set during interpolation control, set so the
major axis side becomes the reference axis. If the minor axis side is set as the
reference axis, the major axis side speed may exceed the "
Pr.8
Speed limit
value".
Limits to interpolation control
There are limits to the interpolation control that can be executed and speed
(
Pr.20
Interpolation speed designation method) that can be set, depending on
the "
Pr.1
Unit setting" of the reference axis and interpolation axis. (For example,
circular interpolation control cannot be executed if the reference axis and
interpolation axis units differ.)
The following table shows the interpolation control and speed designation limits.
Pr.1
Unit setting 1
"
Da.2
Control system"
interpolation control
Pr.20
Interpolation speed
designation method
Reference axis and interpolation
axis units are the same, or a
combination of "mm" and "inch".
3
Reference axis and
interpolation axis units
differ 3
Composite speed
Linear 2 (ABS, INC)
Fixed-feed 2
Reference axis speed
Composite speed
2
Circular sub
(ABS, INC)
Circular right
(ABS, INC)
Circular left
(ABS, INC) Reference axis speed
Composite speed
Linear 3 (ABS, INC)
Fixed-feed 3
Reference axis speed
Composite speed
Linear 4 (ABS, INC)
Fixed-feed 4
Reference axis speed
: Setting possible, : Setting not possible.
1 "mm" and "inch" unit mix possible.
2 "degree" setting not possible. An error "Circular interpolation not possible" (error code: 535) will occur and the
position cannot start if circular interpolation control is set when the unit is "degree". The machine will immediately stop
if "degree" is set during positioning control.
3 The unit set in the reference axis will be used for the speed unit during control if the units differ or if "mm" and "inch"
are combined.
Axis operation status during interpolation control
"Interpolation" will be stored in the "
Md.26
Axis operation status" during
interpolation control. "Standby" will be stored when the interpolation operation is
terminated. Both the reference axis and interpolation axis will carry out a
deceleration stop if an error occurs during control, and "error occurring" will be
stored in the operation status.
Содержание Melsec-Q QD75D1
Страница 1: ......
Страница 2: ......
Страница 22: ...A 20 MEMO ...
Страница 24: ...MEMO ...
Страница 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Страница 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Страница 292: ...MEMO ...
Страница 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Страница 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Страница 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Страница 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 693: ...Appendix 7 MELSEC Q APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse ...
Страница 699: ...Appendix 13 MELSEC Q APPENDICES Initial value Axis 1 Axis 2 Axis 3 Axis 4 Remarks 0 0 0 1 1 0 0 0 0 0 0 300 11 0 0 ...
Страница 836: ...Appendix 150 MELSEC Q APPENDICES Appendix 14 External dimension drawing 1 QD75P1N Unit mm 23 4 27 4 98 90 46 ...
Страница 837: ...Appendix 151 MELSEC Q APPENDICES 2 QD75P2N Unit mm 23 27 4 90 4 98 46 3 QD75P4N 23 27 4 90 4 98 46 Unit mm ...
Страница 838: ...Appendix 152 MELSEC Q APPENDICES 4 QD75D1N 12 90 23 27 4 Unit mm 98 4 46 5 QD75D2N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Страница 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Страница 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Страница 857: ......
Страница 858: ......