12 - 26
MELSEC-Q
12 CONTROL SUB FUNCTIONS
12.4 Functions to limit the control
Functions to limit the control include the "speed limit function", "torque limit function",
"software stroke limit", and "hardware stroke limit". Each function is executed by
parameter setting or sequence program creation and writing.
12.4.1 Speed limit function
The "speed limit function" limits the command speed to a value within the "speed limit
value" setting range when the command speed during control exceeds the "speed limit
value".
The details shown below explain about the "speed limit function".
[1] Relation between the speed limit function and various controls
[2] Control precautions
[3] Setting method
[1] Relation between the speed limit function and various controls
The following table shows the relation of the "speed limit function" and various
controls.
Control type
Speed limit function Speed limit value
Machine OPR control
OPR
control
Fast OPR control
1-axis linear control
2- to 4-axis linear
interpolation control
1-axis fixed-feed control
2- to 4-axis fixed-feed
control (interpolation)
Position
control
2-axis circular interpolation
control
1- to 4-axis Speed control
Speed-position switching control,
Position-speed switching control
Pr.8
Speed limit
value
Current value changing
–
Major
positioning
control
Other
control
JUMP instruction, NOP
instruction, LOOP to
LEND
–
Setting value invalid
JOG operation, Inching operation
Pr.31
JOG speed
limit value
Manual
control
Manual pulse generator operation
–
Setting is invalid
: Always set
– : Setting not required (Setting value is invalid. Use the initial values or setting values
within a range where no error occurs.)
Содержание Melsec-Q QD75D1
Страница 1: ......
Страница 2: ......
Страница 22: ...A 20 MEMO ...
Страница 24: ...MEMO ...
Страница 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Страница 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Страница 292: ...MEMO ...
Страница 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Страница 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Страница 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Страница 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 693: ...Appendix 7 MELSEC Q APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse ...
Страница 699: ...Appendix 13 MELSEC Q APPENDICES Initial value Axis 1 Axis 2 Axis 3 Axis 4 Remarks 0 0 0 1 1 0 0 0 0 0 0 300 11 0 0 ...
Страница 836: ...Appendix 150 MELSEC Q APPENDICES Appendix 14 External dimension drawing 1 QD75P1N Unit mm 23 4 27 4 98 90 46 ...
Страница 837: ...Appendix 151 MELSEC Q APPENDICES 2 QD75P2N Unit mm 23 27 4 90 4 98 46 3 QD75P4N 23 27 4 90 4 98 46 Unit mm ...
Страница 838: ...Appendix 152 MELSEC Q APPENDICES 4 QD75D1N 12 90 23 27 4 Unit mm 98 4 46 5 QD75D2N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Страница 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Страница 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Страница 857: ......
Страница 858: ......