8 - 5
MELSEC-Q
8 OPR CONTROL
8.2.2 Machine OPR method
The method by which the machine OP is established (method for judging the OP position and
machine OPR completion) is designated in the machine OPR according to the configuration
and application of the positioning method.
The following table shows the six methods that can be used for this OPR method.
(The OPR method is one of the items set in the OPR parameters. It is set in "
Pr.43
OPR
method" of the basic parameters for OPR.)
Pr.43
OPR method
Operation details
Near-point dog method
Deceleration starts by the OFF ON of the near-point dog. (Speed is reduced to
" Pr.47 Creep speed".)
The operation stops at the first zero signal after the near-point dog turns from ON
OFF. When a "deviation counter clear output" is completed, the machine OPR is
completed.
Stopper method 1)
The stopper position is regarded as the OP.
After the deceleration starts by the OFF ON of the near-point dog, the machine presses
against the stopper at the " Pr.47 Creep speed" and stops.
The machine OPR is regarded as completed on completion of the deviation counter clear
output provided after " Pr.49 OPR dwell time" passed after stoppage.
Stopper method 2)
The stopper position is regarded as the OP.
After the deceleration starts by the OFF ON of the near-point dog, the machine presses
against the stopper at the " Pr.47 Creep speed" and stops.
The machine OPR is regarded as completed on completion of the deviation counter clear
output provided after the zero signal is detected after stoppage.
Stopper method 3)
The stopper position is regarded as the OP.
The machine starts at the " Pr.47 Creep speed" from the beginning, then presses
against the stopper at the " Pr.47 Creep speed" and stops.
The machine OPR is regarded as completed on completion of the deviation counter clear
output provided after the zero signal is detected after stoppage.
Count method 1)
The deceleration starts by the OFF ON of the near-point dog, and the machine moves
at the " Pr.47 Creep speed".
The machine stops at the zero signal after moving the distance set in the " Pr.50
Setting for the movement amount after near-point dog ON" from the near point dog OFF
ON position. When a "deviation counter clear signal output" is completed, the machine
OPR is regarded as completed.
Count method 2)
The deceleration starts by the OFF ON of the near-point dog, and the machine moves
at the " Pr.47 Creep speed".
The machine moves the distance set in the " Pr.50 Setting for the movement amount
after near-point dog ON" from the near point dog OFF ON position, and stops at that
position. The machine OPR is then regarded as completed.
: The following are the signals input as the zero signals of the QD75 in the corresponding OPR methods.
Near-point dog method, count method 1): Signal that is output as a single pulse at one motor revolution (e.g. Z-phase signal
output from the drive unit)
Stopper method 2), 3)
: Signal that is output on detection of contact with the stopper. (Input externally)
Содержание Melsec-Q QD75D1
Страница 1: ......
Страница 2: ......
Страница 22: ...A 20 MEMO ...
Страница 24: ...MEMO ...
Страница 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Страница 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Страница 292: ...MEMO ...
Страница 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Страница 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Страница 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Страница 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 693: ...Appendix 7 MELSEC Q APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse ...
Страница 699: ...Appendix 13 MELSEC Q APPENDICES Initial value Axis 1 Axis 2 Axis 3 Axis 4 Remarks 0 0 0 1 1 0 0 0 0 0 0 300 11 0 0 ...
Страница 836: ...Appendix 150 MELSEC Q APPENDICES Appendix 14 External dimension drawing 1 QD75P1N Unit mm 23 4 27 4 98 90 46 ...
Страница 837: ...Appendix 151 MELSEC Q APPENDICES 2 QD75P2N Unit mm 23 27 4 90 4 98 46 3 QD75P4N 23 27 4 90 4 98 46 Unit mm ...
Страница 838: ...Appendix 152 MELSEC Q APPENDICES 4 QD75D1N 12 90 23 27 4 Unit mm 98 4 46 5 QD75D2N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Страница 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Страница 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Страница 857: ......
Страница 858: ......