5 - 66
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
Da.10 M code (or condition data No./No. of LOOP to LEND repetitions)
Set an "M code", a "condition data No. ", or the "number of LOOP to LEND
repetitions" depending on how the "
Da.2
Control system" is set.
•
If a method other than "JUMP instruction" and "LOOP" is selected as the
"
Da.2
Control system"
............... Set an "M code".
If no "M code" needs to be output, set "0" (default value).
•
If "JUMP instruction" is selected as the "
Da.2
Control system"
............... Set the "condition data No." for JUMP.
0
: Unconditional JUMP to the positioning data specified
by
Da.9
.
1 to 10 : JUMP performed according to the condition data No.
specified (a number between 1 and 10).
•
If "LOOP" is selected as the "
Da.2
Control system"
............... Set the number of LOOP to LEND repetitions by a number other than
"0".
The error "Control system LOOP setting error" (error code: 545) will
occur if you specify "0".
The condition data specifies the condition for the JUMP instruction to be executed.
(A JUMP will take place when the condition is satisfied.)
[Table 1]
Pr.1
setting value
Value set with peripheral device
(unit)
Value set with sequence program
(unit)
0 : mm
0.01 to 20000000.00 (mm/min)
1 to 2000000000 (
×
10
-2
mm/min)
1 : inch
0.001 to 2000000.000 (inch/min)
1 to 2000000000 (
×
10
-3
inch/min)
2 : degree
0.001 to 2000000.000 (degree/min) 1 to 2000000000 (
×
10
-3
degree/min)
3 : pulse
1 to 1000000 (pulse/s)
1
[QD75P N/QD75D N]
1 to 4000000 (pulse/s)
[QD75P /QD75D ]
1 to 1000000 (pulse/s)
1: In GX Configurator-QP, the QD75P N/QD75D N are recognized as the QD75P /QD75D . Therefore, the
setting ranges are the same as those of the QD75P /QD75D . To set a value outside a setting range in GX
Configurator-QP, set it through a sequence program or GX Works2. The setting ranges in GX Works2 are the
same as those in sequence programs. (Refer to Appendix 1.2)
[Table 2]
Da.2
setting value
Setting item
Value set with peripheral
device
Value set with sequence
program
JUMP instruction: 82
H
Positioning data No.
1 to 600
1 to 600
Other than JUMP instruction
Dwell time
0 to 65535 (ms)
0 to 65535 (ms)
[Table 3]
Da.2
setting value
Setting item
Value set with peripheral
device
Value set with sequence
program
JUMP instruction: 82
H
Condition data No.
0 to 10
0 to 10
LOOP: 83
H
Repetition count
1 to 65535
1 to 65535
Other than the above
M code
0 to 65535
0 to 65535
Содержание Melsec-Q QD75D1
Страница 1: ......
Страница 2: ......
Страница 22: ...A 20 MEMO ...
Страница 24: ...MEMO ...
Страница 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Страница 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Страница 292: ...MEMO ...
Страница 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Страница 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Страница 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Страница 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 693: ...Appendix 7 MELSEC Q APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse ...
Страница 699: ...Appendix 13 MELSEC Q APPENDICES Initial value Axis 1 Axis 2 Axis 3 Axis 4 Remarks 0 0 0 1 1 0 0 0 0 0 0 300 11 0 0 ...
Страница 836: ...Appendix 150 MELSEC Q APPENDICES Appendix 14 External dimension drawing 1 QD75P1N Unit mm 23 4 27 4 98 90 46 ...
Страница 837: ...Appendix 151 MELSEC Q APPENDICES 2 QD75P2N Unit mm 23 27 4 90 4 98 46 3 QD75P4N 23 27 4 90 4 98 46 Unit mm ...
Страница 838: ...Appendix 152 MELSEC Q APPENDICES 4 QD75D1N 12 90 23 27 4 Unit mm 98 4 46 5 QD75D2N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Страница 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Страница 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Страница 857: ......
Страница 858: ......