12.5.2 Override function
The "override function" changes the command speed by a designated percentage (1 to
300%) for all control to be executed.
The speed can be changed by setting the percentage (%) by which the speed is
changed in "
Cd.13
Positioning operation speed override".
[1] Control details
[2] Control precautions
[3] Setting method
[1] Control details
The following shows that operation of the override function.
1) A value changed by the override function is monitored by "
Md.22
Feedrate". (When
Md.22
" becomes "0", the warning "Less than minimum
speed" (warning code: 110) is generated and the axis is controlled in the
then speed unit of "1".)
2) If "
Cd.13
Positioning operation speed override" is set to 100%, the speed
will not change.
3) If "
Cd.13
Positioning operation speed override" is set a value 100% or
less, the warning "Less than minimum speed" (warning code: 110) is
generated, and control will be carried out at speed unit "1" at the time
"Feedrate" becomes a value of "1" or less.
4) If there is not enough remaining distance to change the speed by the
"override function" during the "position control" or position control by the
"speed-position switching control" or "position-speed switching control", the
operation will be carried out at the possible speed for the distance.
5) If the speed changed by the "override function" is greater than the "
Pr.8
Speed limit value", a warning "Speed limit value over" (warning code: 501)
will occur and the speed will be controlled at the "
Pr.8
Speed limit value".
The "
Md.39 In speed limit flag" will turn ON.
Cd. 13
Da. 8 Command speed
Md. 22 Feedrate
100
1
50
150
100
200
50
50
1
25
75
50
75
Not affected by the override value
during deceleration
Not enough remaining
distance could be secured,
so operation is carried out
at an increased speed.
t
V
Positioning operation
speed override
Fig. 12.30 Override function operation
Содержание Melsec-Q QD75D1
Страница 1: ......
Страница 2: ......
Страница 22: ...A 20 MEMO ...
Страница 24: ...MEMO ...
Страница 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Страница 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Страница 292: ...MEMO ...
Страница 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Страница 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Страница 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Страница 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 693: ...Appendix 7 MELSEC Q APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse ...
Страница 699: ...Appendix 13 MELSEC Q APPENDICES Initial value Axis 1 Axis 2 Axis 3 Axis 4 Remarks 0 0 0 1 1 0 0 0 0 0 0 300 11 0 0 ...
Страница 836: ...Appendix 150 MELSEC Q APPENDICES Appendix 14 External dimension drawing 1 QD75P1N Unit mm 23 4 27 4 98 90 46 ...
Страница 837: ...Appendix 151 MELSEC Q APPENDICES 2 QD75P2N Unit mm 23 27 4 90 4 98 46 3 QD75P4N 23 27 4 90 4 98 46 Unit mm ...
Страница 838: ...Appendix 152 MELSEC Q APPENDICES 4 QD75D1N 12 90 23 27 4 Unit mm 98 4 46 5 QD75D2N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Страница 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Страница 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Страница 857: ......
Страница 858: ......