5 - 62
MELSEC-Q
5 DATA USED FOR POSITIONING CONTROL
When "
Pr.1
Unit Setting" is "inch"
The table below lists the control systems that require the setting of the positioning
address or movement amount and the associated setting ranges.
(With any control system excluded from the table below, neither the positioning
address nor the movement amount needs to be set.)
Da.2
setting value
Value set with peripheral device
(inch)
Value set with sequence program 1
(
×
10
-5
inch)
ABS Linear 1
: 01
H
ABS Linear 2
: 0A
H
ABS Linear 3
: 15
H
ABS Linear 4
: 1A
H
Current value changing
: 81
H
◊
Set the address
-21474.83648 to 21474.83647
◊
Set the address
-2147483648 to 2147483647
INC Linear 1
: 02
H
INC Linear 2
: 0B
H
INC Linear 3
: 16
H
INC Linear 4
: 1B
H
Fixed-feed 1
: 03
H
Fixed-feed 2
: 0C
H
Fixed-feed 3
: 17
H
Fixed-feed 4
: 1C
H
◊
Set the movement amount
-21474.83648 to 21474.83647
◊
Set the movement amount
-2147483648 to 2147483647
Forward run speed/position : 06
H
Reverse run speed/position : 07
H
Forward run position/speed : 08
H
Reverse run position/speed : 09
H
◊
Set the movement amount
0 to 21474.83647
◊
Set the movement amount
0 to 2147483647
ABS circular sub
: 0D
H
ABS circular right
: 0F
H
ABS circular left
: 10
H
◊
Set the address
-21474.83648 to 21474.83647
◊
Set the address
-2147483648 to 2147483647
INC circular sub
: 0E
H
INC circular right
: 11
H
INC circular left
: 12
H
◊
Set the movement amount
-21474.83648 to 21474.83647
◊
Set the movement amount
-2147483648 to 2147483647
1: Set an integer because the sequence program cannot handle fractions.
(The value will be converted properly within the system.)
Содержание Melsec-Q QD75D1
Страница 1: ......
Страница 2: ......
Страница 22: ...A 20 MEMO ...
Страница 24: ...MEMO ...
Страница 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Страница 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Страница 292: ...MEMO ...
Страница 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Страница 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Страница 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Страница 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 693: ...Appendix 7 MELSEC Q APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse ...
Страница 699: ...Appendix 13 MELSEC Q APPENDICES Initial value Axis 1 Axis 2 Axis 3 Axis 4 Remarks 0 0 0 1 1 0 0 0 0 0 0 300 11 0 0 ...
Страница 836: ...Appendix 150 MELSEC Q APPENDICES Appendix 14 External dimension drawing 1 QD75P1N Unit mm 23 4 27 4 98 90 46 ...
Страница 837: ...Appendix 151 MELSEC Q APPENDICES 2 QD75P2N Unit mm 23 27 4 90 4 98 46 3 QD75P4N 23 27 4 90 4 98 46 Unit mm ...
Страница 838: ...Appendix 152 MELSEC Q APPENDICES 4 QD75D1N 12 90 23 27 4 Unit mm 98 4 46 5 QD75D2N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Страница 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Страница 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Страница 857: ......
Страница 858: ......