M-7067D 7 Ch Form A Relay Output DAQ Module

- QuickStart (Apr/2018)  

ICP DAS USA, Inc.

 

www.icpdas-usa.com

 | 1-310-517-9888 | 24309 Narbonne Ave. Suite 200. Lomita, CA 90717

 

 

M-7067D  

7 Channel Form A Relay Output Digital Input 

Data Acquisition Module

 

Quick Start Guide 

Product Website:  

https://www.icpdas-usa.com/m_7067_d.html

  

http://www.icpdas-usa.com/dcon_utility_pro.html

  

1. Introduction 

 

The M-7067D device is a network data acquisition and control module that 
support Modbus RTU. They can be remotely controlled using a set of 
commands called DCON protocol. With the Modbus RTU protocol, it can 
easily communicate with most popular SCADA/ HMI software and PLCs. 
 

2. Terminal Assignment 

 

 

 
 
 
 
 
 

Summary of Contents for M-7067D

Page 1: ...Module Quick Start Guide Product Website https www icpdas usa com m_7067_d html http www icpdas usa com dcon_utility_pro html 1 Introduction The M 7067D device is a network data acquisition and control module that support Modbus RTU They can be remotely controlled using a set of commands called DCON protocol With the Modbus RTU protocol it can easily communicate with most popular SCADA HMI softwar...

Page 2: ... Module QuickStart Apr 2018 ICP DAS USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 2 3 Block Wiring Diagram 4 Default Settings Module Address 01 DIO Type Type 40 Baud Rate 9600 bps Checksum disabled ...

Page 3: ...module follow the steps below 1 Connect the digital input and output 2 Connect the module to the RS 485 network using the DATA and DATA terminals If the host is only equipped with an RS 232 interface then an RS 232 to RS 485 converter will be required 3 Connect the module to the power supply using the Vs and GND terminals Note that the voltage supplied should be in the range of 10 to 30V DC ...

Page 4: ...17 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 4 4 Open DCON utility pro click on COM port first icon It can select multi options such as Baud Rate Protocol Checksum and Format to search module The default settings for the module can be found in Section 3 Click OK after selecting the COM port setting ...

Page 5: ...usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 5 5 DCON utility pro will search for the selected COM port according the setting previously set DCON Utility Pro supports DCON and Modbus protocol for all ICPDAS and the others modules 6 Configuration I O module setting on PC ...

Page 6: ...an send command to the module See user manual Sections 2 for details command Configure the module sending the AANNTTCCFF command See user manual Section 2 for details Read data from the input channels send either the AA or AAN command to the module 8 If user doesn t know command user can select Address and ID it will show some refer commands as below User can select necessary command to test or de...