Appendix - 45
MELSEC-Q
APPENDICES
Appendix 7 Connection examples with servo amplifiers manufactured by SANYO DENKI
Co., Ltd.
Appendix 7.1 Connection example of QD75D N and PYO series (Differential driver)
4
PULSE F+
PULSE R+
CLEAR
CLEAR COM
READY
PULSER A+
PULSER A-
PULSER B+
PULSER B-
B19
A20
B20
DOG
FLS
RLS
STOP
CHG
COM
COM
3
1
2
4
5
15
16
17
18
14
8
24G
P24V
PYO
*3
PPC
5V
A
B
0V
+5V
5G
*1
PULSE F-
PULSE R-
RDY COM
10
PG024
PG0 COM
13
11
12
A19
6
7
PPC
NPC
NPC
CLE
SG
COP
SRDY
DOR-24V
SON
PROT
NROT
SG
26
27
28
29
34
25
11
41
49
37
32
33
13
SG
DC5-24V
24
50
SG
48
Upper limit
Stop
External command
*2
*2
Near-point dog
Lower limit
Within 2m *5
QD75D N
Differential driver
common terminal
Manual pulse
generator
MR-HDP01
REMARK
(1) 1: The logic for each I/O terminal can be changed with "
Pr.22
Input signal logic selection" and "
Pr.23
Output
signal logic selection" in detailed parameters 1. (Negative logic is used for all terminals in the example above.)
(2) 2: The QD75D N upper limit (FLS) and lower limit (RLS) are used in the OPR retry function. Set these signals
inside the servo amplifier limit switches.
(3) 3: Refer to the manual of the servo amplifier for information on the servo amplifier side wiring and various signal
wire shields not shown above.
(4) 4: Use the same logic (positive logic/negative logic) for the QD75D N and servo amplifier. The QD75D N is
initially set to negative logic.
(5) 5: This indicates the distance between the QD75D N and PYO.
Содержание Melsec-Q QD75D1
Страница 1: ......
Страница 2: ......
Страница 22: ...A 20 MEMO ...
Страница 24: ...MEMO ...
Страница 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Страница 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Страница 292: ...MEMO ...
Страница 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Страница 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Страница 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Страница 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 693: ...Appendix 7 MELSEC Q APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse ...
Страница 699: ...Appendix 13 MELSEC Q APPENDICES Initial value Axis 1 Axis 2 Axis 3 Axis 4 Remarks 0 0 0 1 1 0 0 0 0 0 0 300 11 0 0 ...
Страница 836: ...Appendix 150 MELSEC Q APPENDICES Appendix 14 External dimension drawing 1 QD75P1N Unit mm 23 4 27 4 98 90 46 ...
Страница 837: ...Appendix 151 MELSEC Q APPENDICES 2 QD75P2N Unit mm 23 27 4 90 4 98 46 3 QD75P4N 23 27 4 90 4 98 46 Unit mm ...
Страница 838: ...Appendix 152 MELSEC Q APPENDICES 4 QD75D1N 12 90 23 27 4 Unit mm 98 4 46 5 QD75D2N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Страница 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Страница 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Страница 857: ......
Страница 858: ......