9 - 45
MELSEC-Q
9 MAJOR POSITIONING CONTROL
POINT
•
When the movement amount is converted to the actual number of output pulses, a fraction appears after
the decimal point, according to the movement amount per pulse. This fraction is normally retained in the
QD75 and reflected at the next positioning.
For the fixed-feed control, since the movement distance is maintained constant (= the output number of
pulses is maintained constant), the control is carried out after the fractional pulse is cleared to zero at
start.
Accumulation/cutoff for fractional pulses
When movement amount per pulse is 1.0 m and movement for 2.5 m is executed two times;
Conversion to output pulses: 2.5[ m] 1.0 = 2.5 pulses
2.5 m
2.5 m
INC line1
Fixed-feed 1
2 pulses
3 pulses (=2.5+0.5)
2 pulses
2 pulses
Movement
amount
Output pulses
0.5 pulse hold by the QD75 is
carried to next positioning.
0.5 pulse hold by the QD75 is cleared to 0 at start
and not carried to next positioning.
Positioning data setting example
The following table shows setting examples when "1-axis fixed-feed control (fixed-
feed 1)" is set in positioning data No. 1 of axis 1.
Setting item
Setting example
Setting details
Da.1 Operation pattern
Positioning
complete
Set "Positioning complete" assuming the next positioning data will not
be executed.
Da.2 Control system
Fixed-feed 1 Set 1-axis fixed-feed control.
Da.3
Acceleration time
No.
1
Designate the value set in " Pr.25 Acceleration time 1" as the
acceleration time at start.
Da.4
Deceleration time
No.
0
Designate the value set in " Pr.10 Deceleration time 0" as the
deceleration time at deceleration.
Da.5
Axis to be
interpolated
–
Setting not required (setting value will be ignored).
Da.6
Positioning address/
movement amount
8000.0
μ
m
Set the positioning address. (Assuming "mm" is set in " Pr.1 Unit
setting".)
Da.7 Arc address
–
Setting not required (setting value will be ignored).
Da.8 Command speed
6000.00mm/min Set the speed during movement to the positioning address.
Da.9 Dwell time
500ms
Set the time the machine dwells after the positioning stop (pulse output
stop) to the output of the positioning complete signal.
Axis 1 Positioning data N
o. 1
Da.10
M code
10
Set this when other sub operation commands are issued in
combination with the No. 1 positioning data.
* Refer to Section 5.3 "List of positioning data" for information on the setting details.
Содержание Melsec-Q QD75D1
Страница 1: ......
Страница 2: ......
Страница 22: ...A 20 MEMO ...
Страница 24: ...MEMO ...
Страница 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Страница 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Страница 292: ...MEMO ...
Страница 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Страница 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Страница 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Страница 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 693: ...Appendix 7 MELSEC Q APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse ...
Страница 699: ...Appendix 13 MELSEC Q APPENDICES Initial value Axis 1 Axis 2 Axis 3 Axis 4 Remarks 0 0 0 1 1 0 0 0 0 0 0 300 11 0 0 ...
Страница 836: ...Appendix 150 MELSEC Q APPENDICES Appendix 14 External dimension drawing 1 QD75P1N Unit mm 23 4 27 4 98 90 46 ...
Страница 837: ...Appendix 151 MELSEC Q APPENDICES 2 QD75P2N Unit mm 23 27 4 90 4 98 46 3 QD75P4N 23 27 4 90 4 98 46 Unit mm ...
Страница 838: ...Appendix 152 MELSEC Q APPENDICES 4 QD75D1N 12 90 23 27 4 Unit mm 98 4 46 5 QD75D2N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Страница 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Страница 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Страница 857: ......
Страница 858: ......