9 - 86
MELSEC-Q
9 MAJOR POSITIONING CONTROL
9.2.16 Speed-position switching control (INC mode)
In "speed-position switching control (INC mode)" ("
Da.2
Control system" = Forward
run: speed/position, Reverse run: speed/position), the pulses of the speed set in
"
Da.8
Command speed" are kept output on the axial direction set to the positioning
data. When the "speed-position switching signal" is input, position control of the
movement amount set in "
Da.6
Positioning address/movement amount" is exercised.
"Speed-position switching control (INC mode)" is available in two different types:
"forward run: speed/position" which starts the axis in the forward run direction and
"reverse run: speed/position" which starts the axis in the reverse run direction.
Use the detailed parameter 1 "
Pr.150
Speed-position function selection" with regard to
the choice for "speed-position switching control (INC mode)".
Buffer memory address
Setting item
Setting
value
Setting details
Axis 1 Axis 2 Axis 3 Axis 4
Pr.150
Speed-
position
function
selection
0
Speed-position switching control
(INC mode)
34 184 334 484
If the set value is other than 0 and 2, it is regarded as 0 and operation is performed in the
INC mode.
For details of the setting, refer to Section 5.2 "List of parameters".
Switching over from speed control to position control
(1) The control is switched over from speed control to position control by
executing the external command signal set in "speed-position switching
signal".
(2) Besides setting the positioning data, the "
Cd.24
Speed-position switching
enable flag" must also be turned ON to switch over from speed control to
position control. (If the "
Cd.24
Speed-position switching enable flag" turns
ON after the speed-position switching signal turns ON, the control will continue
as speed control without switching over to position control. The control will be
switched over from speed control to position control when the speed-position
switching signal turns from OFF to ON again. Only position control will be
carried out when the "
Cd.24
Speed-position switching enable flag" and
speed-position switching signal are ON at the operation start.)
Buffer memory address
Setting item
Setting
value
Setting details
Axis 1 Axis 2 Axis 3 Axis 4
Cd.24
Speed-
position
switching
enable
flag
1
Set "1: Switch from speed control
to position control when the
external command signal [CHG]
turns ON.".
1528 1628 1728 1828
Содержание Melsec-Q QD75D1
Страница 1: ......
Страница 2: ......
Страница 22: ...A 20 MEMO ...
Страница 24: ...MEMO ...
Страница 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Страница 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Страница 292: ...MEMO ...
Страница 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Страница 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Страница 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Страница 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 693: ...Appendix 7 MELSEC Q APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse ...
Страница 699: ...Appendix 13 MELSEC Q APPENDICES Initial value Axis 1 Axis 2 Axis 3 Axis 4 Remarks 0 0 0 1 1 0 0 0 0 0 0 300 11 0 0 ...
Страница 836: ...Appendix 150 MELSEC Q APPENDICES Appendix 14 External dimension drawing 1 QD75P1N Unit mm 23 4 27 4 98 90 46 ...
Страница 837: ...Appendix 151 MELSEC Q APPENDICES 2 QD75P2N Unit mm 23 27 4 90 4 98 46 3 QD75P4N 23 27 4 90 4 98 46 Unit mm ...
Страница 838: ...Appendix 152 MELSEC Q APPENDICES 4 QD75D1N 12 90 23 27 4 Unit mm 98 4 46 5 QD75D2N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Страница 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Страница 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Страница 857: ......
Страница 858: ......