12 - 82
MELSEC-Q
12 CONTROL SUB FUNCTIONS
Da. 1 Operation pattern
Md. 25 Valid M code
Cd. 7 M code OFF request
11
00
11
Warning occurs at this timing.
t
m1
m3
m2
V
1
OFF
ON
OFF
OFF
ON
ON
0
1 0
0
Positioning start signal
BUSY signal
M code ON signal
Positioning
m1 to m3 indicate set M codes.
[XC, XD, XE, XF]
[Y10, Y11, Y12, Y13]
[X4, X5, X6, X7]
Fig. 12.45 Warning due to an M code ON signal during continuous path control
POINT
If the M code output function is not required, set a "0" in setting item "
Da.10
M
code" of the positioning data.
[3] Control precautions
(1) During interpolation control, the reference axis M code ON signal is turned
ON.
(2) The M code ON signal will not turn ON if "0" is set in "
Da.10
M code". (The
M code will not be output, and the previously output value will be held in
"
Md.25
Valid M code".)
(3) If the M code ON signal is ON at the positioning start, an error "M code ON
signal start" (error code: 536) will occur, and the positioning will not start.
(4) If the PLC READY signal (Y0) is turned OFF, the M code ON signal will turn
OFF and "0" will be stored in "
Md.25
Valid M code".
(5) If the positioning operation time is short during continuous path control, there
will not be enough time to turn OFF the M code ON signal, and a warning "M
code ON signal ON" (warning code: 503) may occur. In this case, set a "0"
in the "
Da.10
M code" of that section's positioning data.
(6) In the AFTER mode during speed control, the M code is not output and the
M code ON signal does not turn ON.
(7) If current value changing where "9003" has been set to "
Cd.3
Positioning
start No." is performed, the M code output function is made invalid.
Содержание Melsec-Q QD75D1
Страница 1: ......
Страница 2: ......
Страница 22: ...A 20 MEMO ...
Страница 24: ...MEMO ...
Страница 41: ...1 17 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 48: ...1 24 MELSEC Q 1 PRODUCT OUTLINE MEMO ...
Страница 60: ...2 12 MELSEC Q 2 SYSTEM CONFIGURATION MEMO ...
Страница 137: ...5 33 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 232: ...5 128 MELSEC Q 5 DATA USED FOR POSITIONING CONTROL MEMO ...
Страница 252: ...6 20 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 253: ...6 21 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL ...
Страница 278: ...6 46 MELSEC Q 6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL MEMO ...
Страница 292: ...MEMO ...
Страница 436: ...9 120 MELSEC Q 9 MAJOR POSITIONING CONTROL MEMO ...
Страница 464: ...10 28 MELSEC Q 10 HIGH LEVEL POSITIONING CONTROL MEMO ...
Страница 638: ...14 24 MELSEC Q 14 DEDICATED INSTRUCTIONS MEMO ...
Страница 647: ...15 9 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 686: ...15 48 MELSEC Q 15 TROUBLESHOOTING MEMO ...
Страница 693: ...Appendix 7 MELSEC Q APPENDICES Axis address mm inch degree pulse Axis address mm inch degree pulse ...
Страница 699: ...Appendix 13 MELSEC Q APPENDICES Initial value Axis 1 Axis 2 Axis 3 Axis 4 Remarks 0 0 0 1 1 0 0 0 0 0 0 300 11 0 0 ...
Страница 836: ...Appendix 150 MELSEC Q APPENDICES Appendix 14 External dimension drawing 1 QD75P1N Unit mm 23 4 27 4 98 90 46 ...
Страница 837: ...Appendix 151 MELSEC Q APPENDICES 2 QD75P2N Unit mm 23 27 4 90 4 98 46 3 QD75P4N 23 27 4 90 4 98 46 Unit mm ...
Страница 838: ...Appendix 152 MELSEC Q APPENDICES 4 QD75D1N 12 90 23 27 4 Unit mm 98 4 46 5 QD75D2N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 839: ...Appendix 153 MELSEC Q APPENDICES 6 QD75D4N 90 23 27 4 12 98 4 46 Unit mm ...
Страница 840: ...Appendix 154 MELSEC Q APPENDICES 7 QD75P1 QD75P2 QD75P4 27 4 23 98 90 4 46 unit mm ...
Страница 841: ...Appendix 155 MELSEC Q APPENDICES 8 QD75D1 QD75D2 QD75D4 27 4 23 90 12 98 4 46 unit mm ...
Страница 842: ...Appendix 156 MELSEC Q APPENDICES MEMO ...
Страница 857: ......
Страница 858: ......