background image

 

 
 
 
 
Specifications 

Output protocols 

Wiegand or RS485 (Model dependent) 

 

BTBIOX/DFBIOX 

BIOMIP2X/BIOXMIP3X 

BTBIOXK/DFBIOXK 

BIOMIP2XK/BIOMIP3XK 

Power requirement 

6 – 18V DC (Nominal operating voltage 12V DC) 

Current consumption 

(12V DC) 

84mA (Average) 

246mA (Peak) 

Relay Rating 

80mA  

Read range 

20-40mm (0.8”-1.6”) at 12V DC depends on the type of card 

used 

Operating 

temperature 

-10’C to +50’C (14’F to 122’F) 

Relative humidity 

90% max, operating non-condensing 

Reader dimensions 

190mm(L) x 119mm(W) x 58mm(D) (7.5”4.7”x2.3”) 

Status LED 

Green & Red Bi-colour, Blue, Orange  

Audible tone 

Internal and external buzzer control 

Keypad (XK only) 

3 x 4 Keypad and 4 Function keys, illuminated 

Colour finish 

Charcoal / Ivory 

IP rating 

IP65 

 

Information obtained in this document is subject to change without notice. 

 

For further technical information, visit our website at www.bqtsolutions.com or email 

[email protected]

 

Alternatively contact us at one of our global locations 

 

 

AUSTRALIA & PACIFIC 

BQT Solutions (Australia) Pty Limited 

Unit 29, 1 Talavera Road 

North Ryde, NSW 2113, Australia 

Phone: +61 (0)2 8817 2800 

Fax: +61 (0)2 8817 2811 

Email: [email protected] 

 

 

EUROPE AND MIDDLE EAST 

BQT Solutions (UK) Limited 

Regus, Castle Court, 41 London Road 

Reigate, RH2 9RJ 

United Kingdom 

Phone: +44 (0)17 3773 5071 

Fax: +44 (0)17 3773 5072 

Email: [email protected] 

 

GREATER ASIA 

BQT Solutions Singapore Office 

Mediapolis 

71 Ayer Rajah Crescent #03-03 

Singapore 139951 

Phone: +65 6220 7970 

Fax: +65 6220 7656 

Email:  [email protected] 

 

 

 
 
 

 

 
 
 

Copyright © 2013 BQT Solutions Limited. BQT Solutions and the BQT solutions logo are registered trademarks of BQT Solutions (Australia) Pty Ltd. 

Wiring diagram 

 

Note: 

 

A shielded cable is recommended to be used. The shield is connected to controller 0V reference 

 

Maximum wiegand data cable length: 150 meters (500 feet)  

 

Buzzer and LED are low activated. 

 

RS485 lines and Relay lines are only for optional use 

 

Terminate or insulate all un-used wires 

 
 

Regulatory Information

 

C-Tick: This device is C-Tick complied.  
CE: The device has passed all relevant tests and obtained CE approval. 
FCC: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device 
may not cause harmful interference and 2) this device must accept any interference received, including interference that may 
cause undesired operation of the device.  
Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 
of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential 
installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance 
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures: 
-Reorient or relocate the receiving antenna. 
-Increase the separation between the equipment and receiver. 
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 
-Consult the dealer or an experienced radio/TV technician for help. 
Any changes or modifications not expressively approved by BQT Solutions could void the user’s authority to operate this 
equipment. 

 
 
 
 

 

                             

 

 

 
 
 

 

 
 
 
 

BioX/XK

 