Appendix
97
BTU/lbs
> 7.200
Colorific value
MJ/kg
>16,5
Lb/cft
> 40,00
Bulk density
kg/m³
>600
Water content
Mass%
<10
Ash content
Mass%
<1
Inch
1 1/4 – 1 1/2
Lenght
mm
3,15 – 40
Inch
1/4 – 5/16
Diameter
mm
6,00 – 8,00
Fine material
Mass%
<0.5
Mass%
<1%
Ash melting point
°F
> 2.200
°C
> 1.200
Contents
USA
untreated wood
Europe
stemwood or chemically untreated wood
Components
Gal
5,68
6,81
-
Internal ash pan volume
lb
25
30
-
Gal
4,54
5,675
External ash box volume
lb
20
25
Main Drive
W
40
Drive Motor
W
250/370
Suction Turbine
W
1200
Combustion Air Blower
W
83
Suction Fan Blower
W
32
Electrical Ignition
W
250
Cleaning Motor
W
40
Motor External Ash Box
W
40
Fire protection motor
W
5
The data are values of the test measurement and can vary from locally measured values
WB Federal Institute of Agricultural Engineering Wieselburg
Address: A-3250 Wieselburg, Rottenhauserstraße 1; Tel.: +43-7416-52175-0
Note:
Test reports are available at MEco
PE 3671 USA 2.3
Installation Manual PES 36–56
Содержание Pellematic PES 12-20
Страница 38: ...Connecting up to the power supply 38 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 46: ...Connecting up to the power supply 46 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 47: ...Connecting up to the power supply 47 PE 3671 USA 2 3 Installation Manual PES 36 56...
Страница 52: ...Operating the pellet boiler 52 Setting date and time Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 88: ...Appendix 88 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 92: ...Appendix 92 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 99: ...Appendix 99 Labeling 105x74 PE 3671 USA 2 3 Installation Manual PES 36 56...
Страница 100: ......