background image

ITW Food Equipment Group, LLC 
3600 North point Blvd. 
Baltimore, MD 21222 

RETAIN THIS MANUAL FOR FUTURE USE

 

FORM F-36952 (06-08)

 

INSTALLATION & OPERATION MANUAL FOR 

Charbroilers 

 

 

 

 

 

MODELS 

MLS 

VCCB25 

ML-114540

 

VCCB30 

ML-114541

 

VCCB36 

ML-114542

 

VCCB47 

ML-114543

 

VCCB60 

ML-114544

 

VCCB72 

ML-114545

 

www.vulcanhart.com 

 

 
 

 

 

 

MODELS 

MLS 

SCB25 

ML-767100

 

SCB30 

ML-767101

 

SCB36 

ML-767102

 

SCB47 

ML-767103

 

SCB60 

ML-767104

 

SCB72 

ML-767105

 

www.wolfrange.com 

 

 

 

 
 
 
 
 
 

 

VCCB36

Содержание SCB25

Страница 1: ... 06 08 INSTALLATION OPERATION MANUAL FOR Charbroilers MODELS MLS VCCB25 ML 114540 VCCB30 ML 114541 VCCB36 ML 114542 VCCB47 ML 114543 VCCB60 ML 114544 VCCB72 ML 114545 www vulcanhart com MODELS MLS SCB25 ML 767100 SCB30 ML 767101 SCB36 ML 767102 SCB47 ML 767103 SCB60 ML 767104 SCB72 ML 767105 www wolfrange com VCCB36 ...

Страница 2: ...PORTANT IN THE EVENT A GAS ODOR IS DETECTED SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE I...

Страница 3: ... 13 188 500 INSTALLATION UNPACKING Immediately after unpacking check for possible shipping damage If the broiler is found to be damaged save the packaging material and contact the carrier within 15 days of delivery Before installing verify that the type of gas natural or propane and the clearance dimensions see page 4 agree with the specifications on the rating plate which is located on the lower ...

Страница 4: ...power means of exhaust shall comply with 248 CMR 3 NFPA Standard 96 Vapor Removal from Cooking Equipment latest edition available from the National Fire Protection Association Batterymarch Park Quincy MA 02269 In Canada 1 Local codes 2 CAN CSA B149 1 Natural Gas Installation latest edition 3 CAN CSA B149 2 Propane Installation Code latest edition available from the Canadian Gas Association 178 Rex...

Страница 5: ... show any appreciable drop When testing the gas supply piping system if test pressures exceed psig 3 45 kPa the charbroiler and its individual shutoff valve must be disconnected from the gas supply piping system When test pressures are psig 3 45 kPa or less the charbroiler must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing...

Страница 6: ...pped with legs turn the feet at the bottom of the legs in or out to level the broiler in the final installed location If the broiler is mounted on the optional stand equipped with casters position the charbroiler on a level floor VENTILATION HOOD The broiler should be installed under a suitable ventilation hood For safe operation and proper ventilation keep the space between the charbroiler and ve...

Страница 7: ...reheat for 30 minutes Rub grates with cooking oil before using Note that grease runs forward and drips into the trough in front of the charbroiler before draining into the grease drawer COMPONENT PARTS The charbroiler comes with several standard parts as illustrated Each can be easily removed and installed easily by hand for cleaning and maintenance Note that the Burner and Deflector are an assemb...

Страница 8: ... bolted to the floor The stand includes a top shelf with marine edges style lip and a lower shelf When mounted on a stand with standard legs and properly leveled the cooking surface should approximately 36 from the floor GRATES The charbroiler has a variety of optional grate accessories Refer to your current catalog for pricing and availability CAST SLANTED GRATE Standard grate used on all charbro...

Отзывы: