background image

Catalog No.:  2000.203E 

Effective:  12-1-07 

Replaces:  4-1-05

 

Job: 

 

           

 

Engineer: 

 

           

 

Contractor: 

 

           

 

Prepared By: 

            

 Date:

              

 

Model:  

           

 

Indoor 

   

LOW NOx 

 

Less than 40 nanograms per joule 

EFFICIENT 

 

82% efficiency – highest of any atmospheric boiler 
available today 

THERMAL SHOCK PROOF 

 

Twenty-year warranty against thermal shock damage 
up to 150°F differential 

 

Maximum operating temperature: 230°F 

LIGHTWEIGHT 

 

A floor load of 70 lbs./sq. ft. or less 

HIGH RECOVERY 

 

Cuts fuel costs substantially because the standby and 
radiation losses normal to other boilers and 
tank-type water heaters are eliminated 

LOW WATER OPERATING TEMPERATURE 

 

Operates with water temperature as low as 
105°F without condensing 

 

Heat Exchanger 

ƒ

  ASME Inspected and Stamped 

160 PSIG 

ƒ

  National Board Approved 

ƒ

 Headers 

 Cast Iron Glass-lined – Standard 
 Bronze – Option A-1 

ƒ

 Finned 

Tubing 

 Copper – Standard 
 Cupro Nickel – Option A-3 

ƒ

  ASME Steel Tube Sheet 

ƒ

 Silicone 

O-Rings 

ƒ

  ASME Pressure Relief Valve 

 45 PSIG – Standard 
            PSIG ASME – Optional  

ƒ

  Temperature and Pressure Gauge, 

Shipped Loose 

ƒ

 Water 

Connections 

 Left Hand – Standard 
 Right Hand – Option A-6 

ƒ

  Flow Configuration – Two-pass 

ƒ

  Pump – Optional 

 Mounted, 1/8 HP

120 V, 1

,

 60 Hz 

Controls 

ƒ

  120V, 60Hz, 1 Ph Power Supply 

ƒ

 120/24V 

Transformer 

ƒ

  100% Pilot Shut-off/Lockout 

ƒ

 Electronic, 

Intermittent Ignition (IID) Pilot 

Controls (cont'd) 

ƒ

  High Limit Control, Manual Reset 

ƒ

 On/Off 

Switch 

ƒ

 Flow 

Switch 

ƒ

  Economaster II Pump Time Delay 

Gas Train 

ƒ

 Natural 

Gas 

ƒ

  Manual Main Gas Shut-off Cock 

ƒ

  Main Gas Pressure Regulator 

ƒ

  Redundant Safety Shut-off Valve 

ƒ

  Control Valve         

ƒ

 Firing 

Mode 

 On/off (H4) 
 Two-stage firing (H3) 

ƒ

 Design 

Certified 

ANSI Z21.13 H Stamp 

Construction 

ƒ

 Front 

Controls 

ƒ

  Stainless Steel, Fan-Assisted 

Burners 

ƒ

  Polytuf Powder Coat Finish 

ƒ

 Draft 

Diverter 

ƒ

  Base – Optional  

 Combustible Floor Shield –  

Option J-1   

 
 

Temperature Controls 

 B-6 

2-stage Aquastat –  
100-200ºF 

 B-26  2-stage Digital Controller 
 B-27  2-stage Digital Controller, 

Outdoor Reset 

 Y-241 Electronic Sequencer,  

1-4 Stages 

 

 Y-281 Electronic Sequencer,  

1-8 Stages 

Additional Safety Controls 

 F-10  Low Water Cut-off Probe 
 I-1 

High Limit Control, Auto 
Reset 

 S-1 

Low Gas Pressure Switch 

 S-2 

High Gas Pressure Switch 

                       

 

                       

 

Regulatory Agency Requirements 

            

 

            

 

 

 
 

 

 

 

 

 

Raytherm

®

 

- Type H

Hydronic Heating Boilers

Models 181-401 - Indoor 

Low NOx

Отзывы: