Appendix
96
Inch WC
0,03 / 0,01
Draft at max/min Power
mbar
0,08 / 0,03
°F
320
Flue gas temperature
rated power (Flue gas
temperature can be
adjusted)
°C
160
°F
212
Flue gas temperature
partial load (Flue gas
temperature can be
adjusted)
°C
100
Lb/hr
49,60
62,17
82,89
99,43
115,96
149,25
198,85
231,92
Flue gas inertia current
rated power
kg/h
22,50
28,20
37,60
45,10
52,60
67,70
90,20
105,20
Lb/hr
14,11
20,72
24,91
29,76
35,71
45,64
62,17
70,33
Flue gas inertia current
partial load
kg/h
6,40
9,40
11,30
13,50
16,20
20,70
28,20
31,90
Cft/hr
918
1.232
1.642
1.971
2.627
2.956
3.941
4.598
Flue gas volume rated
power
m³/h
26
35
47
56
74
84
112
130
Cft/hr
240
353
424
509
607
777
1.059
1.204
Flue gas volume partial
load
m³/h
7
10
12
14
17
22
30
34
Chimney diameter
according to chimney calculation
Chimney construction
steel or ceramic lined, withstand humidity
USA
208 VAC, 60 Hz, 6A for auger delivery system, 16A for vacuum suction
system
Electrical connection
EU
230 VAC, 50 Hz, 6A for auger delivery system, 16A for vacuum suction
system
Water area
Inch WC
38,22
60,22
88,32
114,02
150,95
15,62
20,84
24,29
Water resistance at 10K
mbar
95,20
150,00
220,00
284,00
376,00
38,90
51,90
60,50
Inch WC
9,72
15,26
22,08
28,91
38,14
4,18
5,58
6,50
Water resistance at 20K
mbar
24,20
38,00
55,00
72,00
95,00
10,40
13,90
16,20
°F
149 - 194
Boiler temperature
°C
65 - 90
°F
131
Boiler input temperature
minimum
°C
55
psi
50
Operating pressure
maximum
bar
3,50
psi
67
Test pressure
bar
4,60
Cft/hr
1.010,0 1.327,8 1.772,8 2.231,9 2.874,6 3.217,2 4.262,5 4.944,1
Flue gas volume rated
power at flue gas
temperature
m³/h
28,6
37,6
50,2
63,2
81,4
91,1
120,7
140,0
Cft/hr
243,7
384,9
459,1
614,5
769,9
847,6
1.165,4 1.313,7
Flue gas volume
partial load at flue gas
temperature
m³/h
6,9
10,9
13,0
17,4
21,8
24,0
33,0
37,2
USA
According to PFI Standards
Fuel
Europe
According to EN14961–2 Standards (A1 Class)
Installation Manual PES 36–56
PE 3671 USA 2.3
Содержание Pellematic PES 12-20
Страница 38: ...Connecting up to the power supply 38 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 46: ...Connecting up to the power supply 46 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 47: ...Connecting up to the power supply 47 PE 3671 USA 2 3 Installation Manual PES 36 56...
Страница 52: ...Operating the pellet boiler 52 Setting date and time Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 88: ...Appendix 88 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 92: ...Appendix 92 Installation Manual PES 36 56 PE 3671 USA 2 3...
Страница 99: ...Appendix 99 Labeling 105x74 PE 3671 USA 2 3 Installation Manual PES 36 56...
Страница 100: ......